FAP - Miscellaneous Module - No or wrong function
TASK 23-73-00-810-915-A
FAP - Miscellaneous Module - No or wrong function
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-316-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-646-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-317-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:56 UTC
FAP - Miscellaneous Module - No or wrong function
1. Possible Causes
- Miscellaneous Module
- FAP [120RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-000-005 | Removal of the Miscellaneous Module |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-12-400-005 | Installation of the Miscellaneous Module |
Subtask 23-73-00-710-316-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Push on the FAP 120RH on the Miscellaneous Modul the related switches to control the system.
4. Fault Isolation(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Push on the FAP 120RH on the Miscellaneous Modul the related switches to control the system.
Subtask 23-73-00-810-646-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-647-A ** ON A/C NOT FOR ALL B. If there is no maintenance message, but one or more function controls are not possible from the Miscellaneous Module:
5. Close-up- replace the Miscellaneous Module AMM 23-73-12-000-005 and AMM 23-73-12-400-005:
- replace the FAP [120RH] AMM 23-73-12-000-002 and AMM 23-73-12-400-002.
- do the trouble shooting of the related system.
Subtask 23-73-00-710-317-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.