FAP - Light Module - No or wrong function
TASK 23-73-00-810-913-A
FAP - Light Module - No or wrong function
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-314-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-644-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-315-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:21 UTC
FAP - Light Module - No or wrong function
1. Possible Causes
- Light Module
- FAP [120RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-000-003 | Removal of the Light Module |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-12-400-003 | Installation of the Light Module |
Subtask 23-73-00-710-314-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Push on the FAP 120RH on the Light Modul the related switches to control the effected Light system.
4. Fault Isolation(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Push on the FAP 120RH on the Light Modul the related switches to control the effected Light system.
Subtask 23-73-00-810-644-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-645-A ** ON A/C NOT FOR ALL B. If there is no maintenance message, but one or more function controls are not possible from the Light Module:
5. Close-up- replace the Light Module AMM 23-73-12-000-003 and AMM 23-73-12-400-003:
- replace the FAP [120RH] AMM 23-73-12-000-002 and AMM 23-73-12-400-002.
- do the trouble shooting of the related light system.
Subtask 23-73-00-710-315-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.