W DOC AIRBUS | TSM A320F

CIDS MISMATCH - CAM or Director with incorrect part number


TASK 23-73-00-810-907-A
CIDS MISMATCH - CAM or Director with incorrect part number


1. Possible Causes
  • CAM 115RH,
  • DIR-CIDS, 1 [101RH]
  • DIR-CIDS, 2 [102RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-19-000-001
Removal of the Cabin Assignment Module
AMM 23-73-19-400-001
Installation of the Cabin Assignment Module
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-303-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-620-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-621-A ** ON A/C NOT FOR ALL
B. If the fault is confirmed:
5. Close-up
Subtask 23-73-00-710-304-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:56 UTC