CIDS MISMATCH - CAM or Director with incorrect part number
TASK 23-73-00-810-907-A
CIDS MISMATCH - CAM or Director with incorrect part number
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-303-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-620-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-304-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:56 UTC
CIDS MISMATCH - CAM or Director with incorrect part number
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-19-000-001 | Removal of the Cabin Assignment Module |
| AMM 23-73-19-400-001 | Installation of the Cabin Assignment Module |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-303-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-620-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-621-A ** ON A/C NOT FOR ALL B. If the fault is confirmed:
5. Close-up- make sure that components with the correct partnumber are installed for:
-CAM 115RH,
AMM 23-73-19-000-001 and AMM 23-73-19-400-001,
- DIR-CIDS, 1 [101RH] ,
- DIR-CIDS, 2 [102RH] ,
AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
Subtask 23-73-00-710-304-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.