CFDS - Mandatory Layout or Emergency Mode in use
TASK 23-73-00-810-903-A
CFDS - Mandatory Layout or Emergency Mode in use
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-295-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-609-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-296-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:56 UTC
CFDS - Mandatory Layout or Emergency Mode in use
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237309 | |
| AMM 23-73-18-000-001 | Removal of the Programming and Test Panel |
| AMM 23-73-18-400-001 | Installation of the Programming and Test Panel |
| AMM 23-73-19-000-001 | Removal of the Cabin Assignment Module |
| AMM 23-73-19-400-001 | Installation of the Cabin Assignment Module |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-295-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS BITE test AMM 23-73-00-740-005.
(2) On CFDS select:
4. Fault Isolation(1) Do the CIDS BITE test AMM 23-73-00-740-005.
(2) On CFDS select:
- <SYSTEM REPORT/TEST
- <COM
- <CIDS1
- <TEST
Subtask 23-73-00-810-609-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-610-A ** ON A/C NOT FOR ALL B. If the CIDS1 - TEST gives the maintenance message MANDATORY LAYOUT OR EMERGENCY MODE IN USE and on the GROUND SCANNING page the message NO PTP DATA:
Subtask 23-73-00-810-611-A ** ON A/C NOT FOR ALL - replace the PROGRAMMING AND TEST PANEL [110RH] AMM 23-73-18-000-001 and AMM 23-73-18-400-001.
- do a check and repair the wiring between:
CB 161RH and PTP connector A/17,
DIR-CIDS (101RH) connector AA/F12 and PTP (110RH) connector A/1,
DIR_CIDS (101RH) connector AA/G12 and PTP (110RH) connector A/2,
DIR-CIDS (102RH) connector AA/F12 and PTP (110RH) connector A/6,
DIR-CIDS (102RH) connector AA/G12 and PTP (110RH) connector A/7,
DIR-CIDS (101RH) connector AA/J12 and PTP (100RH) connector A/4,
DIR-CIDS (101RH) connector AA/K12 and PTP (110RH) connector A/5,
DIR-CIDS (102RH) connector AA/J12 and PTP (110RH) connector A/4,
DIR-CIDS (102RH) connector AA/K12 and PTP (110RH) connector A/5,
PTP (110RH) connector A/3 and GND,
PTP (110RH) connector A/8 and GND,
PTP (110RH) connector A/16 and GND ASM 237309.
- replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
C. If the CIDS1 - TEST gives the maintenance message MANDATORY LAYOUT OR EMERGENCY MODE IN USE and on the GROUND SCANNING page the message NO CAM DATA:
5. Close-up- replace the MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-000-001 and AMM 23-73-19-400-001.
Subtask 23-73-00-710-296-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.