No PA and no Interphone from both AFT ATTND Stations
TASK 23-73-00-810-902-A
No PA and no Interphone from both AFT ATTND Stations
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-293-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-608-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-710-294-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:56 UTC
No PA and no Interphone from both AFT ATTND Stations
1. Possible Causes
- DEU-B [300RH5]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-47-000-001 | Removal of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-47-400-001 | Installation of the Decoder/Encoder Unit B (300RH) |
| AMM 25-62-00-210-001 | Check Door and Offwing Escape Slide/Raft Inflation Reservoir Pressure |
Subtask 23-73-00-710-293-A ** ON A/C NOT FOR ALL
A. Do this test:
4. Fault Isolation| ACTION | RESULT |
|---|---|
| 1.On the Programming and Test Panel (PTP): | On the PTP: |
|
|
| |
|
|
Subtask 23-73-00-810-608-A ** ON A/C NOT FOR ALL
A. If the DEU-B 300RH5 failure message comes on:
5. Close-up- replace the DEU-B [300RH5] AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
NOTE: If no spare DEU-B is available and to avoid AOG due to two inoperative ATTND stations it is possible to swap DEU-B 300RH5 with DEU-B 300RH4.
Ignore the SLIDE PRESS LOW message on the PTP generated by the swapped faulty DEU-B 300RH5. To make sure that the pressure gage of the RH offwing slide inflation-reservoir is in the correct range do the Inspection/Check procedure of the offwing slide inflation-reservoir AMM 25-62-00-210-001.
Ignore the SLIDE PRESS LOW message on the PTP generated by the swapped faulty DEU-B 300RH5. To make sure that the pressure gage of the RH offwing slide inflation-reservoir is in the correct range do the Inspection/Check procedure of the offwing slide inflation-reservoir AMM 25-62-00-210-001.
Subtask 23-73-00-710-294-A ** ON A/C NOT FOR ALL
A. Do this test:
NOTE: In case you have swapped the DEU-B 300RH5 with DEU-B 300RH4 ignore the failure message generated by the faulty DEU-B on the position of DEU-B 300RH4.
| ACTION | RESULT |
|---|---|
| 1.On the Programming and Test Panel (PTP): | On the PTP: |
|
|
| |
|
|