W DOC AIRBUS | TSM A320F

Director 2 fault


TASK 23-73-00-810-895-A
Director 2 fault


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-710-003
Operational Test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-005
Operational Test of the Passenger Address (PA) system
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-865-056-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUCOM/CIDS/DIR ESS/1150RHG01
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR NORM/1151RHM05
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/DIR NORM/1151RHM06
Subtask 23-73-00-710-280-A ** ON A/C NOT FOR ALL
B. Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
Subtask 23-73-00-710-280-B ** ON A/C NOT FOR ALL
B. Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
Subtask 23-73-00-710-280-D ** ON A/C NOT FOR ALL
B. Test
   (1) Open these Circuit Breakers (CB):
  • 49VU: 150RH CIDS/DIR ESS/1
  • 121VU: 151RH CIDS/DIR NORM/1
   (2) Do an Operational test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-003.
   (3) Do an Operational test of the Passenger Address (PA) System
AMM 23-73-00-710-005.
   (4) Do the CIDS Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
   (5) Close these CBs:
  • 49VU: 150RH CIDS/DIR ESS/1
  • 121VU: 151RH CIDS/DIR NORM/1
   (6) If the tests from the steps (1) through (5) are OK:
  • Ignore the ECAM Warning and / or Maintenance Message(s):
    CIDS 1+2 FAULT
    CIDS 2.
4. Fault Isolation
Subtask 23-73-00-810-593-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-594-A ** ON A/C NOT FOR ALL
B. If the CIDS BITE test gives the maintenance message DIRECTOR:
  • do the CIDS2 DIRECTOR test through the CFDS.
   (1) If the fault message DIRECTOR comes on:
Subtask 23-73-00-810-594-B ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
Subtask 23-73-00-710-283-A
C. Do the test as given in Para 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:55 UTC