Director 2 fault
TASK 23-73-00-810-895-A
Director 2 fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-865-056-A
Subtask 23-73-00-810-593-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:55 UTC
Director 2 fault
1. Possible Causes
- DIR-CIDS, 2 [102RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-710-003 | Operational Test of the Cabin and Flight Crew Interphone System |
| AMM 23-73-00-710-005 | Operational Test of the Passenger Address (PA) system |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-865-056-A
A. Table of the circuit breakers used in this procedure:
Subtask 23-73-00-710-280-A ** ON A/C NOT FOR ALL Subtask 23-73-00-710-280-B ** ON A/C NOT FOR ALL Subtask 23-73-00-710-280-D ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M06 |
B. Test
(1) Open these Circuit Breakers (CB):
AMM 23-73-00-710-003.
(3) Do an Operational test of the Passenger Address (PA) System
AMM 23-73-00-710-005.
(4) Do the CIDS Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
(5) Close these CBs:
4. Fault Isolation(1) Open these Circuit Breakers (CB):
- 49VU: 150RH CIDS/DIR ESS/1
- 121VU: 151RH CIDS/DIR NORM/1
AMM 23-73-00-710-003.
(3) Do an Operational test of the Passenger Address (PA) System
AMM 23-73-00-710-005.
(4) Do the CIDS Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
(5) Close these CBs:
- 49VU: 150RH CIDS/DIR ESS/1
- 121VU: 151RH CIDS/DIR NORM/1
- Ignore the ECAM Warning and / or Maintenance Message(s):
CIDS 1+2 FAULT
CIDS 2.
Subtask 23-73-00-810-593-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-594-A ** ON A/C NOT FOR ALL B. If the CIDS BITE test gives the maintenance message DIRECTOR:
Subtask 23-73-00-810-594-B ** ON A/C NOT FOR ALL - do the CIDS2 DIRECTOR test through the CFDS.
- replace the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
B. If the test confirms the fault:
Subtask 23-73-00-710-283-A - replace the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
C. Do the test as given in Para 3.A.