W DOC AIRBUS | TSM A320F

Director 1 fault


TASK 23-73-00-810-894-A
Director 1 fault


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-710-003
Operational Test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-005
Operational Test of the Passenger Address (PA) system
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-279-A ** ON A/C NOT FOR ALL
A. Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
Subtask 23-73-00-710-279-B ** ON A/C NOT FOR ALL
A. Do the CIDS Interface and Power-Up test through the CFDS AMM 23-73-00-740-005.
Subtask 23-73-00-710-279-D ** ON A/C NOT FOR ALL
A. Test
   (1) Do an Operational test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-003.
   (2) Do an Operational test of the Passenger Address (PA) System
AMM 23-73-00-710-005.
   (3) Do the CIDS1 Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
   (4) If the tests from the steps (1) through (3) are OK:
  • Ignore the ECAM Warning and / or Maintenance Message:
    CIDS 1+2 FAULT
    CIDS 1.
4. Fault Isolation
Subtask 23-73-00-810-591-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-592-A ** ON A/C NOT FOR ALL
B. If the CIDS BITE test gives the maintenance message DIRECTOR:
Subtask 23-73-00-810-592-B ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
Subtask 23-73-00-710-285-A
C. Do the test as given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:55 UTC