Director 1 fault
TASK 23-73-00-810-894-A
Director 1 fault
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-279-A ** ON A/C NOT FOR ALL Subtask 23-73-00-710-279-B ** ON A/C NOT FOR ALL Subtask 23-73-00-710-279-D ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-591-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:55 UTC
Director 1 fault
1. Possible Causes
- DIR-CIDS, 1 [101RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-710-003 | Operational Test of the Cabin and Flight Crew Interphone System |
| AMM 23-73-00-710-005 | Operational Test of the Passenger Address (PA) system |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-279-A ** ON A/C NOT FOR ALL Subtask 23-73-00-710-279-B ** ON A/C NOT FOR ALL Subtask 23-73-00-710-279-D ** ON A/C NOT FOR ALL
A. Test
(1) Do an Operational test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-003.
(2) Do an Operational test of the Passenger Address (PA) System
AMM 23-73-00-710-005.
(3) Do the CIDS1 Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
(4) If the tests from the steps (1) through (3) are OK:
4. Fault Isolation(1) Do an Operational test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-003.
(2) Do an Operational test of the Passenger Address (PA) System
AMM 23-73-00-710-005.
(3) Do the CIDS1 Interface and Power-Up test through the CFDS
AMM 23-73-00-740-005.
(4) If the tests from the steps (1) through (3) are OK:
- Ignore the ECAM Warning and / or Maintenance Message:
CIDS 1+2 FAULT
CIDS 1.
Subtask 23-73-00-810-591-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-592-A ** ON A/C NOT FOR ALL B. If the CIDS BITE test gives the maintenance message DIRECTOR:
Subtask 23-73-00-810-592-B ** ON A/C NOT FOR ALL - replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
B. If the test confirms the fault:
Subtask 23-73-00-710-285-A - replace the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
C. Do the test as given in Para. 3.A.