CIDS - No CIDS function in 50% of the cabin
TASK 23-73-00-810-881-A
CIDS - No CIDS function in 50% of the cabin
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-267-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-574-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:55 UTC
CIDS - No CIDS function in 50% of the cabin
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- DEU-A 200RH
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| ASM 237307 | |
| ASM 237308 | |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 23-73-46-000-001 | Removal of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-46-400-001 | Installation of the Decoder/Encoder Unit A (200RH) |
Subtask 23-73-00-710-267-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 23-73-00-810-574-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-575-F ** ON A/C NOT FOR ALL B. If the CFDS gives the maintenance message:
50% DEU-A
DEU-A 200RHXX (all effected DEU-A 200RH are shown)
Subtask 23-73-00-710-268-A ** ON A/C NOT FOR ALL 50% DEU-A
DEU-A 200RHXX (all effected DEU-A 200RH are shown)
- make sure that at least one cabin door is open.
- make sure that the EMER LT (4WL) switch is in the OFF position,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2, - wait for approx. 10 s and close the CB 156RH and 157RH,
- stop for approx. 120 s,
- do the CIDS BITE test again.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- replace all related DEU-A 200RH AMM 23-73-46-000-001 and AMM 23-73-46-400-001.
- do a check and repair the wiring between the related:
DEU mount connector A/8 and CB 163RH,
DEU mount connector A/8 and CB 164RH,
DEU mount connector A/8 and CB 165RH,
DEU mount connector A/8 and CB 166RH,
DEU mount connector A/8 and CB 167RH,
DEU mount connector A/8 and CB 168RH,
DEU mount connector A/5 and CB 154RH,
DEU mount connector A/5 and CB 155RH,
DEU mount connector A/7 and GND
ASM 237306, ASM 237307 and ASM 237308.
C. Do the test as given in Para. 3.A.