W DOC AIRBUS | TSM A320F

CIDS - No CIDS function in 50% of the cabin


TASK 23-73-00-810-881-A
CIDS - No CIDS function in 50% of the cabin


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DEU-A 200RH
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237306
ASM 237307
ASM 237308
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 23-73-46-000-001
Removal of the Decoder/Encoder Unit A (200RH)
AMM 23-73-46-400-001
Installation of the Decoder/Encoder Unit A (200RH)
3. Fault Confirmation
Subtask 23-73-00-710-267-A ** ON A/C NOT FOR ALL
A. Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-73-00-810-574-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-575-F ** ON A/C NOT FOR ALL
B. If the CFDS gives the maintenance message:

50% DEU-A
DEU-A 200RHXX (all effected DEU-A 200RH are shown)

  • make sure that at least one cabin door is open.
  • make sure that the EMER LT (4WL) switch is in the OFF position,
  • open these CBs:
    49VU: 150RH (G01) COM DIR ESS/1
    49VU: 157RH (G02) COM DIR ESS/2
    121VU:151RH (M06) CIDS/DIR NORM/1
    121VU:156RH (M07) CIDS/DIR NORM/2,
  • wait for approx. 10 s and close the CB 156RH and 157RH,
  • stop for approx. 120 s,
  • do the CIDS BITE test again.
   (1) If the test is OK:
   (2) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring between the related:
    DEU mount connector A/8 and CB 163RH,
    DEU mount connector A/8 and CB 164RH,
    DEU mount connector A/8 and CB 165RH,
    DEU mount connector A/8 and CB 166RH,
    DEU mount connector A/8 and CB 167RH,
    DEU mount connector A/8 and CB 168RH,
    DEU mount connector A/5 and CB 154RH,
    DEU mount connector A/5 and CB 155RH,
    DEU mount connector A/7 and GND
    ASM 237306, ASM 237307 and ASM 237308.
Subtask 23-73-00-710-268-A ** ON A/C NOT FOR ALL
C. Do the test as given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:55 UTC