W DOC AIRBUS | TSM A320F

PSIU - No Pax Call from two or three PSIUs in series


TASK 23-73-00-810-876-A
PSIU - No Pax Call from two or three PSIUs in series


1. Possible Causes
  • DEU-A (200RHxx)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-710-007
Operational Test of the Passenger Call System
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-46-000-001
Removal of the Decoder/Encoder Unit A (200RH)
AMM 23-73-46-400-001
Installation of the Decoder/Encoder Unit A (200RH)
3. Fault Confirmation
Subtask 23-73-00-710-238-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
   (2) Do the operational test of the passenger call system AMM 23-73-00-710-007.
4. Fault Isolation
Subtask 23-73-00-810-529-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-530-A ** ON A/C NOT FOR ALL
B. If the test shows a fault in two or three PSU/PSIUs in series:
Subtask 23-73-00-710-239-A ** ON A/C NOT FOR ALL
C. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:54 UTC