ACP - No indication on one Area Call Panel
TASK 23-73-00-810-870-A
ACP - No indication on one Area Call Panel
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-184-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-432-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:54 UTC
ACP - No indication on one Area Call Panel
1. Possible Causes
- lamp
- DEU-B 300RH
- ACP 340RHx
- wiring
- ACP 340RHxx
- DEU-B 300RHxx
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-710-035 | Operational Test of the Cabin LED lamps through the MCDU |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-11-000-001 | Removal of the Area Call Panel |
| AMM 23-73-11-400-001 | Installation of the Area Call Panel |
| ASM 237324 | |
| ASM 237327 | |
| AMM 23-73-47-000-001 | Removal of the Decoder/Encoder Unit B (300RH) |
| AMM 23-73-47-400-001 | Installation of the Decoder/Encoder Unit B (300RH) |
Subtask 23-73-00-710-184-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Do the CIDS1/AREA CALL PANELS test through the CFDS.
Subtask 23-73-00-710-184-B ** ON A/C NOT FOR ALL (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Do the CIDS1/AREA CALL PANELS test through the CFDS.
A. Test
(1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
(2) Do the Operational Test of the Cabin LED Lamps via the CFDS AMM 23-73-00-710-035.
4. Fault Isolation(1) Do the CIDS Interface and Power-Up Test via the CFDS AMM 23-73-00-740-005.
(2) Do the Operational Test of the Cabin LED Lamps via the CFDS AMM 23-73-00-710-035.
Subtask 23-73-00-810-432-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-433-A ** ON A/C NOT FOR ALL B. If the CIDS BITE test result is no fault message, but there is a fault in the related ACP:
Subtask 23-73-00-810-433-C ** ON A/C NOT FOR ALL - replace the related lamp .
- operate the ACPs through the CFDS1/AREA CALL PANELS test,
- do a check for 28 VDC at the related DEU-B 300RHx connector B1,B2,B3,B4,B9, B10,B11 and B12 ASM 237324 and ASM 237327.
- replace the related DEU-B 300RH AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- replace the related ACP 340RHx AMM 23-73-11-000-001 and AMM 23-73-11-400-001.
- do a check and repair the wiring between the:
DEU-B 300RHx connector B/1(9) and ACP 340RHx pin 1,
DEU-B 300RHx connector B/2(10) and ACP 340RHx pin 2,
DEU-B 300RHx connector B/3(11) and ACP 340RHx pin 3,
DEU-B 300RHx connector B/4(12) and ACP 340RHx pin 4,
ACP 340RHx pin 5 and GND ASM 237324 and ASM 237327.
B. If the CIDS Interface and Power-Up Test result is no fault message, but there is a fault in the related ACP:
Subtask 23-73-00-710-190-A - replace the related ACP 340RHxx AMM 23-73-11-000-001 and AMM 23-73-11-400-001.
- do a check for 28 VDC at the related DEU-B 300RHxx connector B1,B2,B3,B4,B9, B10,B11 and B12 ASM 237324 and ASM 237327.
- replace the related DEU-B 300RHxx AMM 23-73-47-000-001 and AMM 23-73-47-400-001.
- do a check and repair the wiring between the:
DEU-B 300RHxx connector B/1(9) and ACP 340RHxx pin 1,
DEU-B 300RHxx connector B/2(10) and ACP 340RHxx pin 2,
DEU-B 300RHxx connector B/3(11) and ACP 340RHxx pin 3,
DEU-B 300RHxx connector B/4(12) and ACP 340RHxx pin 4,
ACP 340RHxx pin 5 and GND ASM 237324 and ASM 237327.
C. Do the test given in Para. 3.A.