W DOC AIRBUS | TSM A320F

PA - No PA and cabin interphone from two and more cabin handsets


TASK 23-73-00-810-865-A
PA - No PA and cabin interphone from two and more cabin handsets


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DEU-B 300RHx
  • DEU-B
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-710-003
Operational Test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-005
Operational Test of the Passenger Address (PA) system
AMM 23-73-00-710-021
Operational Test of the Cabin and Flight Crew Interphone System
AMM 23-73-00-710-022
Operational Test of the Passenger Address (PA) system
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 23-73-47-000-001
Removal of the Decoder/Encoder Unit B (300RH)
AMM 23-73-47-400-001
Installation of the Decoder/Encoder Unit B (300RH)
3. Fault Confirmation
Subtask 23-73-00-710-164-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS.
AMM 23-73-00-740-005
   (2) Do the operational test of the Passenger Address (PA) system.
AMM 23-73-00-710-005
   (3) Do the operational test of the Cabin and Flight Crew Interphone system.
AMM 23-73-00-710-003
Subtask 23-73-00-710-164-C ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
   (2) Do the operational test of the Passenger Address (PA) system.
AMM 23-73-00-710-005
   (3) Do the operational test of the Cabin and Flight Crew Interphone system.
AMM 23-73-00-710-003
Subtask 23-73-00-710-164-D ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
   (2) Do the operational test of the Passenger Address (PA) system.
AMM 23-73-00-710-022
   (3) Do the operational test of the Cabin and Flight Crew Interphone system.
AMM 23-73-00-710-021
4. Fault Isolation
Subtask 23-73-00-810-389-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-390-D ** ON A/C NOT FOR ALL
B. If there is no maintenance message, but there is a fault in one or both of the operational tests for two or more handsets:
  • make sure that at least one cabin door is open.
  • make sure that the EMER LT (4WL) switch is in the OFF position.
  • open these CBs:
    49VU: 150RH (G01) COM DIR ESS/1
    49VU: 157RH (G02) COM DIR ESS/2
    121VU:151RH (M06) CIDS/DIR NORM/1
    121VU:156RH (M07) CIDS/DIR NORM/2,
  • wait for approx. 10 s and close the CBs 156RH and 157RH.
  • stop for approx. 120 s,
  • do the operational tests again.
   (1) If the tests are OK:
   (2) If the fault continues:
Subtask 23-73-00-810-390-F ** ON A/C NOT FOR ALL
B. If there is no maintenance message, but there is a fault in one or both of the operational tests for two or more handsets:
  • make sure that at least one cabin door is open.
  • open these CBs:
    49VU: 150RH COM/CIDS/DIR ESS/1,
    49VU: 157RH COM/CIDS/DIR ESS/2,
    49VU: 15WH AIR COND/CIDS/SDF/DIR 1 ESS,
    49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
    120VU: 151RH COM NAC/CIDS/DIR NORM/1,
    120VU: 156RH COM NAV/CIDS/DIR NORM/2,
    122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
    122VU: 17WH AIR COND/CIDS/SDF/DIR NORM/1.
  • wait for approx. 10s and close the CBs 156RH, 157RH, 14WH and 18WH.
  • stop for approx. 120s,
  • do the operational tests again.
   (1) If the tests are OK:
   (2) If the fault continues:
Subtask 23-73-00-810-390-G ** ON A/C NOT FOR ALL
B. If there is no maintenance message, but there is a fault in one or both of the operational tests for two or more handsets:
  • make sure that at least one cabin door is open.
  • open these CBs:
    make sure that the EMER LT (4WL) is set to the OFF position.
    49VU: 150RH COM/CIDS/DIR ESS/1,
    49VU: 157RH COM/CIDS/DIR ESS/2,
    49VU: 15WH AIR COND/CIDS/SDF/DIR 1 ESS,
    49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS,
    120VU: 151RH COM NAC/CIDS/DIR NORM/1,
    120VU: 156RH COM NAV/CIDS/DIR NORM/2,
    122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
    122VU: 17WH AIR COND/CIDS/SDF/DIR NORM/1.
  • wait for approx. 10s and close the CBs 156RH, 157RH, 14WH and 18WH.
  • stop for approx. 120s.
  • do the operational tests again.
   (1) If the tests are OK:
   (2) If the fault continues:
Subtask 23-73-00-810-391-A
C. Install the removed DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
Subtask 23-73-00-710-189-A
D. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:25:53 UTC