W DOC AIRBUS | TSM A320F

CAM - Fault in the Cabin Assignment Module data transfer


TASK 23-73-00-810-860-A
CAM - Fault in the Cabin Assignment Module data transfer


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-19-000-001
Removal of the Cabin Assignment Module
AMM 23-73-19-400-001
Installation of the Cabin Assignment Module
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-069-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
   (2) Open this CB for approx. 10 s then close it again:
  • 121VU: 161RH CIDS/PROG AND/TST PNL.
4. Fault Isolation
Subtask 23-73-00-810-070-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-544-D ** ON A/C NOT FOR ALL
B. If the CIDS BITE test gives the maintenance message NO CAM DATA:
  • make sure that at least one cabin door is open,
  • make sure that the EMER LT (4WL) switch is in the OFF position,
  • open these CBs:
    49VU: 150RH (G01) COM DIR ESS/1
    49VU: 157RH (G02) COM DIR ESS/2
    121VU:151RH (M06) CIDS/DIR NORM/1
    121VU:156RH (M07) CIDS/DIR NORM/2,
  • wait for approx. 10 s and close the CBs 156RH and 157RH.
  • stop for approx. 120 s,
  • do the CIDS2 BITE test.
   (1) If CIDS2 BITE test does not give the maintenance message NO CAM DATA:
     (a) If the fault continues:
Subtask 23-73-00-810-566-A ** ON A/C NOT FOR ALL
C. Install the removed DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
Subtask 23-73-00-710-260-A ** ON A/C NOT FOR ALL
D. Do the test given in Para. 3.A.