FAP - FAP(x) no data from active Director
TASK 23-73-00-810-858-A
FAP - FAP(x) no data from active Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-071-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-072-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:53 UTC
FAP - FAP(x) no data from active Director
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237309 | |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-000-007 | Removal of the Flight Attendant Panel |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-12-400-007 | Installation of the Flight Attendant Panel |
| ASM 237323 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-071-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS1/FAP test through the CFDS.
Subtask 23-73-00-710-071-B ** ON A/C NOT FOR ALL 4. Fault Isolation(1) Do the CIDS1/FAP test through the CFDS.
Subtask 23-73-00-810-072-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-156-D ** ON A/C NOT FOR ALL B. If the CIDS1/FAP test gives the maintenance message NO FAP DATA:
Subtask 23-73-00-810-156-F ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- make sure that the EMER LT (4WL) switch is in the OFF position,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1
121VU:156RH (M07) CIDS/DIR NORM/2, - wait for approx. 10 s and close the CBs 156RH and 157RH.
- wait for approx. 120 s,
- do the CIDS2/FAP test.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- replace the FAP [120RH] AMM 23-73-12-000-002 and AMM 23-73-12-400-002
- do a check and repair the wiring between:
DIR-CIDS (101RH) connector AA/A12 and FAP (120RH) connector A/1,
DIR-CIDS (101RH) connector AA/B12 and FAP (120RH) connector A/2,
DIR-CIDS (101RH) connector AA/D12 and FAP (120RH) connector A/4,
DIR-CIDS (101RH) connector AA/E12 and FAP (120RH) connector A/5,
CB 170RH and FAP (120RH) connector A/18,
FAP (120RH) connector A/3 and GND,
FAP (120RH) connector A/6 and GND,
FAP (120RH) connector A/17 and GND ASM 237309.
B. If the test confirms the fault:
Subtask 23-73-00-810-157-A ** ON A/C NOT FOR ALL Subtask 23-73-00-710-224-A - install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
- do the CIDS Interface and Power-Up test through the CFDS.
- replace the FAP FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007
- do a check and repair the wiring between:
DIR-CIDS (101RH) connector AA/5A and FAP (120RH) connector A/1,
DIR-CIDS (101RH) connector AA/5B and FAP (120RH) connector A/2,
DIR-CIDS (101RH) connector AA/13C and FAP (120RH) connector A/3,
DIR-CIDS (101RH) connector AA/13D and FAP (120RH) connector A/4,
CB 170RH and FAP (120RH) connector A/18,
FAP (120RH) connector A/20 and GND,
FAP (120RH) connector A/21 and GND,
FAP (120RH) connector A/22 and GND.
ASM 237323
D. Do the test given in Para. 3.A.