CAM/FAP - Fault in the CAM or FAP
TASK 23-73-00-810-857-A
CAM/FAP - Fault in the CAM or FAP
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-068-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-545-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:53 UTC
CAM/FAP - Fault in the CAM or FAP
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- CAM
- PROGRAMMING AND TEST PANEL [110RH]
- MODULE-CABIN ASSIGNMENT [115RH]
- FAP [120RH]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| AMM 23-73-12-000-007 | Removal of the Flight Attendant Panel |
| AMM 23-73-12-400-007 | Installation of the Flight Attendant Panel |
| AMM 23-73-18-000-001 | Removal of the Programming and Test Panel |
| AMM 23-73-18-400-001 | Installation of the Programming and Test Panel |
| AMM 23-73-19-000-001 | Removal of the Cabin Assignment Module |
| AMM 23-73-19-000-002 | Removal of the Cabin Assignment Module |
| AMM 23-73-19-400-001 | Installation of the Cabin Assignment Module |
| AMM 23-73-19-400-002 | Installation of the Cabin Assignment Module |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-068-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Open this CB for approx. 10s and then close it again:
Subtask 23-73-00-710-068-B ** ON A/C NOT FOR ALL 4. Fault Isolation(1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
(2) Open this CB for approx. 10s and then close it again:
- 121VU: 161RH CIDS/PROG AND/TST PNL.
Subtask 23-73-00-810-545-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-069-D ** ON A/C NOT FOR ALL B. If the CIDS BITE test gives the maintenance message CAM:
Subtask 23-73-00-810-069-F ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open.
- make sure that the EMER LT (4WL) switch is in the OFF position.
- open these CBs:
49VU: 150RH COM DIR ESS/1,
49VU: 157RH COM DIR ESS/2,
121VU: 151RH CIDS/DIR NORM/1,
121VU: 156RH CIDS/DIR NORM/2. - wait for approx. 10s and close the CBs 156RH and 157RH.
- stop for approx. 120s,
- do the CIDS2 BITE test.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- replace the CAM AMM 23-73-19-000-001 and AMM 23-73-19-400-001.
- replace the PROGRAMMING AND TEST PANEL [110RH] AMM 23-73-18-000-001 and AMM 23-73-18-400-001.
B. If the test confirms the fault:
Subtask 23-73-00-810-567-A ** ON A/C NOT FOR ALL Subtask 23-73-00-710-261-A - replace the CAM MODULE-CABIN ASSIGNMENT [115RH] AMM 23-73-19-000-002 and AMM 23-73-19-400-002.
- install a new FAP FAP [120RH] AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
D. Do the test given in Para. 3.A.