TASK 23-73-00-810-857-A
CAM/FAP - Fault in the CAM or FAP


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • CAM
  • PROGRAMMING AND TEST PANEL [110RH]
  • MODULE-CABIN ASSIGNMENT [115RH]
  • FAP [120RH]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-12-000-007
Removal of the Flight Attendant Panel
AMM 23-73-12-400-007
Installation of the Flight Attendant Panel
AMM 23-73-18-000-001
Removal of the Programming and Test Panel
AMM 23-73-18-400-001
Installation of the Programming and Test Panel
AMM 23-73-19-000-001
Removal of the Cabin Assignment Module
AMM 23-73-19-000-002
Removal of the Cabin Assignment Module
AMM 23-73-19-400-001
Installation of the Cabin Assignment Module
AMM 23-73-19-400-002
Installation of the Cabin Assignment Module
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-73-00-710-068-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS BITE test through the CFDS AMM 23-73-00-740-005.
   (2) Open this CB for approx. 10s and then close it again:
  • 121VU: 161RH CIDS/PROG AND/TST PNL.
Subtask 23-73-00-710-068-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-545-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-069-D ** ON A/C NOT FOR ALL
B. If the CIDS BITE test gives the maintenance message CAM:
  • make sure that at least one cabin door is open.
  • make sure that the EMER LT (4WL) switch is in the OFF position.
  • open these CBs:
    49VU: 150RH COM DIR ESS/1,
    49VU: 157RH COM DIR ESS/2,
    121VU: 151RH CIDS/DIR NORM/1,
    121VU: 156RH CIDS/DIR NORM/2.
  • wait for approx. 10s and close the CBs 156RH and 157RH.
  • stop for approx. 120s,
  • do the CIDS2 BITE test.
   (1) If the CIDS2 BITE test does not give the maintenance message CAM:
     (a) If the fault continues:
       1 If the fault continues:
Subtask 23-73-00-810-069-F ** ON A/C NOT FOR ALL
B. If the test confirms the fault:
   (1) If the fault continues:
Subtask 23-73-00-810-567-A ** ON A/C NOT FOR ALL
C. Install the removed DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
Subtask 23-73-00-710-261-A
D. Do the test given in Para. 3.A.