FAP - Fault in the Forward Attendant Panel
TASK 23-73-00-810-838-A
FAP - Fault in the Forward Attendant Panel
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-056-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-865-057-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:38:59 UTC
FAP - Fault in the Forward Attendant Panel
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 237309 | |
| AMM 23-73-12-000-002 | Removal of the Forward Attendant Panel |
| AMM 23-73-12-400-002 | Installation of the Forward Attendant Panel |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
Subtask 23-73-00-710-056-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the FAP test through the CFDS.
4. Fault Isolation(1) Do the FAP test through the CFDS.
Subtask 23-73-00-865-057-A ** ON A/C NOT FOR ALL
A. Table of the circuit breakers used in this procedure:
Subtask 23-73-00-810-057-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/2 | 157RH | G02 |
| 49VU | COM/CIDS/DIR ESS/1 | 150RH | G01 |
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| 121VU | COM NAV/CIDS/DIR NORM/1 | 151RH | M05 |
B. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-145-A ** ON A/C NOT FOR ALL C. If the CFDS gives the maintenance message FWD ATTND PNL:
Subtask 23-73-00-810-146-F ** ON A/C NOT FOR ALL - replace the FAP [120RH] AMM 23-73-12-000-002 and AMM 23-73-12-400-002.
D. If the fault continues:
Subtask 23-73-00-810-147-A ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- make sure that the EMER LT (4WL) switch is in the OFF position,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M05) CIDS/DIR NORM/1
121VU:156RH (M06) CIDS/DIR NORM/2, - wait for approx. 10 s and close the CBs 156RH and 157RH.
- stop for approx. 120 s,
- do the FAP test again.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
E. If the fault continues:
Subtask 23-73-00-810-148-A ** ON A/C NOT FOR ALL Subtask 23-73-00-810-149-A ** ON A/C NOT FOR ALL - do a check and repair the wiring between:
CB 170RH and the FAP (120RH) connector A/18,
DIR-CIDS (101RH) connector AA/A12 and FAP (120RH) connector A/1,
DIR-CIDS (101RH) connector AA/B12 and FAP (120RH) connector A/2,
DIR-CIDS (101RH) connector AA/D12 and FAP (120RH) connector A/4,
DIR-CIDS (101RH) connector AA/E12 and FAP (120RH) connector A/5,
DIR-CIDS (102RH) connector AA/A12 and FAP (120RH) connector A/7,
DIR-CIDS (102RH) connector AA/B12 and FAP (120RH) connector A/8,
DIR-CIDS (102RH) connector AA/D12 and FAP (120RH) connector A/4,
DIR-CIDS (102RH) connector AA/E12 and FAP (120RH) connector A/5,
FAP (120RH) connector A/3 and GND,
FAP (120RH) connector A/6 and GND,
FAP (120RH) connector A/17 and GND ASM 237309.
G. Do the test given in Para. 3.A.