CIDS - Fault in CIDS TOP BUS 2 R
TASK 23-73-00-810-835-A
CIDS - Fault in CIDS TOP BUS 2 R
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-055-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-056-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:51 UTC
CIDS - Fault in CIDS TOP BUS 2 R
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- DIR-CIDS, 2 [102RH]
- DEU-A [200RH24]
- DEU-A [200RH20]
- DEU-A [200RH14]
- DEU-A [200RH10]
- DEU-A [200RH6]
- DEU-A [200RH2]
- DEU mount 2014VU2
- DEU mount 2010VU20
- wiring
- DEU mount 2010VU14
- DEU mount 2010VU10
- DEU mount 2010VU6
- DEU mount 2010VU2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 23-73-46-000-001 | Removal of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-46-400-001 | Installation of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-48-000-001 | Removal of the DEU A/DEU B - Mount |
| AMM 23-73-48-400-001 | Installation of the DEU A/DEU B - Mount |
Subtask 23-73-00-710-055-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS1/CIDS BUS test through the MCDU/CFDS.
(2) Do the CIDS1/DEU-A test through the MCDU/CFDS.
4. Fault Isolation(1) Do the CIDS1/CIDS BUS test through the MCDU/CFDS.
(2) Do the CIDS1/DEU-A test through the MCDU/CFDS.
Subtask 23-73-00-810-056-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-138-F ** ON A/C NOT FOR ALL B. If the CIDS1/CIDS BUS test gives the maintenance message TOP LINE 2R:
Subtask 23-73-00-810-473-A ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- On the overhead-panel 25VU:
make sure that the EMER EXIT LT switch (4WL) is in the OFF position, - remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
- close these CBs:
49VU: 157RH (G02) CIDS/DIR 2/ESS,
121VU:156RH (M07) CIDS/DIR 2/NORM, - wait for approx. 120 s,
- do the CIDS2/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH (G02) CIDS/DIR 2/ESS,
121VU:156RH (M07) CIDS/DIR 2/NORM, - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- do the CIDS1/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001
- make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/F15 and connector AA/G15 is between approx. 80 and 200 ohms ASM 237306.
- make sure that the resistance (line to GND) is not less than 50 ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/F15 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/G15 and GND. ASM 237306
- remove the DEU-A [200RH24] AMM 23-73-46-000-001
- install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- do the CIDS BITE test through the MCDU/CFDS AMM 23-73-00-740-005.
- install a new DEU-A [200RH24] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH24] AMM 23-73-46-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEUs until the maintenance message stops: ASM 237306
DEU-A [200RH20]
DEU-A [200RH14]
DEU-A [200RH10]
DEU-A [200RH6]
DEU-A [200RH2]
- remove the DEU-A [200RH24] AMM 23-73-46-000-001
- do a check for a short circuit again.
- install a new DEU-A [200RH24] AMM 23-73-46-400-001.
- disconnect the electrical connector 7253VC2 from the DEU mount 2014VU2 AMM 23-73-48-000-001.
- do a check for a short circuit again.
- install a new DEU mount 2014VU2 AMM 23-73-48-000-001 and AMM 23-73-48-400-001.
- remove the DEU-A [200RH20] AMM 23-73-46-000-001
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-A [200RH20] AMM 23-73-46-400-001.
- b.2. If the fault continues:
- install the removed DEU-A [200RH24] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU mount 2014VU2 AMM 23-73-48-400-001,
- disconnect the electrical connector 7213VC20 from the DEU mount 2010VU20 AMM 23-73-48-000-001,
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the connector 7213VC20 between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU mount 2010VU20 and the DEU mount 2014VU2 ASM 237306.
- b.2.1.2. If there is no short circuit:
- install a new DEU mount 2010VU20 AMM 23-73-48-400-001.
- b.2.2. If there is a short circuit:
- install the removed DEU-A [200RH20] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU mount 2010VU20 AMM 23-73-48-400-001,
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEUs and DEU mounts until the maintenance message stops: ASM 237306
DEU-A [200RH14] and DEU mount 2010VU14 ,
DEU-A [200RH10] and DEU mount 2010VU10 ,
DEU-A [200RH6] and DEU mount 2010VU6 ,
DEU-A [200RH2] and DEU mount 2010VU2 .
- disconnect the electrical connector 7253VC2 from the DEU mount 2014VU2 AMM 23-73-48-000-001,
- make sure that the resistance (line to line) is not more than 200 ohms (open circuit) between:
DEU mount 2014VU2 pin A/1 and pin A/2
- install a new DEU mount 2014VU2 AMM 23-73-48-400-001
- reconnect the electrical connector to the DEU mount 2014VU2 AMM 23-73-48-400-001
- disconnect the electrical connector 7213VC2 from the DEU mount 2010VU2 AMM 23-73-48-000-001,
- do a check of the wiring (continuity-check) between:
DIR-CIDS (101RH) connector AA/D15 and the connector 7213VC2 pin A/1,
DIR-CIDS (101RH) connector AA/E15 and the connector 7213VC2 pin A/2.
- repair the wiring between the DIR-CIDS (101RH) and the connector 7213VC2 ASM 237306.
- do a check of the wiring (continuity-check) between:
DEU mount 2010VU2 pin A/1 and pin A/9 ,
DEU mount 2010VU2 pin A/2 and pin A/10.
- install a new DEU mount 2010VU2 AMM 23-73-48-000-001 and AMM 23-73-48-400-001
- reconnect the connector 7213VC2 to the DEU mount 2010VU2 AMM 23-73-48-400-001
- do the steps 4. B. (6) again for the subsequent DEU mounts until the maintenance message stops:
DIR-CIDS (101RH) and DEU mount 2010VU6 /connector 7213VC6,
DIR-CIDS (101RH) and DEU mount 2010VU10 /connector 7213VC10,
DIR-CIDS (101RH) and DEU mount 2010VU14 /connector 7213VC14,
DIR-CIDS (101RH) and DEU mount 2010VU20 /connector 7213VC20,
DIR-CIDS (101RH) and DEU mount 2014VU2 /connector 7253VC2.
- remove the DEU-A [200RH24] AMM 23-73-46-000-001.
- do a check for a short circuit again.
- install a new DEU-A [200RH24] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH24] AMM 23-73-46-400-001.
- diconnect the electrical connector 7253VC2 from the DEU mount 2014VU2 ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU mount 2014VU2 AMM 23-73-48-400-001,
- do the steps 4. B. (7) again for the subsequent DEUs and DEU mounts until the maintenance message stops: ASM 237306
DEU-A [200RH20] and DEU mount 2010VU20 ,
DEU-A [200RH14] and DEU mount 2010VU14 ,
DEU-A [200RH10] and DEU mount 2010VU10 ,
DEU-A [200RH6] and DEU mount 2010VU6 ,
DEU-A [200RH2] and DEU mount 2010VU2 .
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
- repaire the wiring between the related DEU mount 2010VUxx and the DEU mount 2014VUxx/2010VUxx ASM 237306.
- install a new DEU mount 2014VU2 AMM 23-73-48-400-001.
C. Installation of removed components
Subtask 23-73-00-810-474-A ** ON A/C NOT FOR ALL - Install the removed DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Install all the removed DEU-A (200RHxx) AMM 23-73-46-400-001.
- Reconnect all the DEU-mount-connectors to the related DEU-mounts (2010VUxx/2014VUx) AMM 23-73-48-400-001.
D. Do the test given in Para. 3.A.