CIDS - Fault in CIDS TOP BUS 1 R / Director 1
TASK 23-73-00-810-834-A
CIDS - Fault in CIDS TOP BUS 1 R / Director 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-079-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-080-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:50 UTC
CIDS - Fault in CIDS TOP BUS 1 R / Director 1
1. Possible Causes
- DIR-CIDS, 1 [101RH]
- DIR-CIDS, 2 [102RH]
- DEU-A [200RH26]
- DEU-A [200RH22]
- DEU-A [200RH18]
- DEU-A [200RH12]
- DEU-A [200RH8]
- DEU-A [200RH4]
- DEU mount 2014VU4
- DEU mount 2010VU22
- wiring
- DEU mount 2010VU18
- DEU mount 2010VU12
- DEU mount 2010VU8
- DEU mount 2010VU4
- DEU-A [200RH16]
- DEU-A [200RH14]
- DEU-A [200RH2]
- DEU TERMINATION BOX [209RH2]
- DEU CONNECTION BOX [208RH14]
- DEU CONNECTION BOX [208RH12]
- DEU CONNECTION BOX [208RH8]
- DEU CONNECTION BOX [208RH4]
- DEU CONNECTION BOX [208RH2]
- DEU-A [200RH10]
- DEU-A [200RH6]
- DEU CONNECTION BOX [208RH10]
- DEU CONNECTION BOX [208RH6]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| AMM 23-73-34-000-001 | Removal of the CIDS Director |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 23-73-42-000-001 | Removal of the Connection Box (208RH,308RH) |
| AMM 23-73-42-400-001 | Installation of the Connection Box (208RH,308RH) |
| AMM 23-73-43-000-001 | Removal of the Termination Box (209RH,309RH) |
| AMM 23-73-43-400-001 | Installation of the Termination Box (209RH,309RH) |
| AMM 23-73-46-000-001 | Removal of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-46-400-001 | Installation of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-48-000-001 | Removal of the DEU A/DEU B - Mount |
| AMM 23-73-48-400-001 | Installation of the DEU A/DEU B - Mount |
Subtask 23-73-00-710-079-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS1/CIDS BUS test through the MCDU/CFDS.
(2) Do the CIDS1/DEU-A test through the MCDU/CFDS.
Subtask 23-73-00-710-079-B ** ON A/C NOT FOR ALL 4. Fault Isolation(1) Do the CIDS1/CIDS BUS test through the MCDU/CFDS.
(2) Do the CIDS1/DEU-A test through the MCDU/CFDS.
Subtask 23-73-00-810-080-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-136-F ** ON A/C NOT FOR ALL B. If the CIDS1/CIDS BUS test gives the maintenance message TOP LINE 1R:
Subtask 23-73-00-810-136-J ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- On the overhead-panel 25VU:
make sure that the EMER EXIT LT switch (4WL) is in the OFF position, - remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
- close these CBs:
49VU: 157RH (G02) CIDS/DIR 2/ESS,
121VU:156RH (M07) CIDS/DIR 2/NORM, - wait for approx. 120 s,
- do the CIDS2/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH (G02) CIDS/DIR 2/ESS,
121VU:156RH (M07) CIDS/DIR 2/NORM, - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- do the CIDS1/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001
- open these CBs:
49VU: 154RH COM/CIDS/DEU A ESS/LINE 1
49VU: 155RH COM/CIDS/DEU A ESS/LINE 2
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD
121VU: 166RH COM NAV/CIDS/DEU A NORM/R MID
121VU: 168RH COM NAV/CIDS/DEU A NORM/R AFT - make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/A15 and connector AA/B15 is between approx. 80 and 200 ohms ASM 237306.
- make sure that the resistance (line to GND) is not less than 50 ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/A15 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/B15 and GND. ASM 237306
- remove the DEU-A [200RH26] AMM 23-73-46-000-001
- install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- close these CBs:
49VU: 154RH COM/CIDS/DEU A ESS/LINE 1
49VU: 155RH COM/CIDS/DEU A ESS/LINE 2
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD
121VU: 166RH COM NAV/CIDS/DEU A NORM/R MID
121VU: 168RH COM NAV/CIDS/DEU A NORM/R AFT - do the CIDS BITE test through the MCDU/CFDS AMM 23-73-00-740-005.
- install a new DEU-A [200RH26] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH26] AMM 23-73-46-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEUs until the maintenance message stops: ASM 237306
DEU-A [200RH22]
DEU-A [200RH18]
DEU-A [200RH12]
DEU-A [200RH8]
DEU-A [200RH4]
- remove the DEU-A [200RH26] AMM 23-73-46-000-001
- do a check for a short circuit again.
- install a new DEU-A [200RH26] AMM 23-73-46-400-001.
- disconnect the electrical connector 7253VC4 from the DEU mount 2014VU4 AMM 23-73-48-000-001.
- do a check for a short circuit again.
- install a new DEU mount 2014VU4 AMM 23-73-48-000-001 and AMM 23-73-48-400-001.
- remove the DEU-A [200RH22] AMM 23-73-46-000-001
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-A [200RH22] AMM 23-73-46-400-001.
- b.2. If the fault continues:
- install the removed DEU-A [200RH22] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU mount 2014VU4 AMM 23-73-48-400-001,
- disconnect the electrical connector 7213VC22 from the DEU mount 2010VU22 AMM 23-73-48-000-001,
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the connector 7213VC22 between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU mount 2010VU22 and the DEU mount 2014VU4 ASM 237306.
- b.2.1.2. If there is no short circuit:
- install a new DEU mount 2010VU22 AMM 23-73-48-400-001.
- b.2.2. If there is a short circuit:
- install the removed DEU-A [200RH22] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU mount 2010VU22 AMM 23-73-48-400-001,
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEUs and DEU mounts until the maintenance message stops: ASM 237306
DEU-A [200RH18] and DEU mount 2010VU18 ,
DEU-A [200RH12] and DEU mount 2010VU12 ,
DEU-A [200RH8] and DEU mount 2010VU8 ,
DEU-A [200RH4] and DEU mount 2010VU4 .
- disconnect the electrical connector 7253VC4 from the DEU mount 2014VU4 AMM 23-73-48-000-001,
- make sure that the resistance (line to line) is not more than 200 ohms (open circuit) between:
DEU mount 2014VU4 pin A/1 and pin A/2
- install a new DEU mount 2014VU4 AMM 23-73-48-400-001
- reconnect the electrical connector to the DEU mount 2014VU4 AMM 23-73-48-400-001
- disconnect the electrical connector 7213VC4 from the DEU mount 2010VU4 AMM 23-73-48-000-001,
- do a check of the wiring (continuity-check) between:
DIR-CIDS (101RH) connector AA/A15 and the connector 7213VC4 pin A/1,
DIR-CIDS (101RH) connector AA/B15 and the connector 7213VC4 pin A/2.
- repair the wiring between the DIR-CIDS (101RH) and the connector 7213VC4 ASM 237306.
- do a check of the wiring (continuity-check) between:
DEU mount 2010VU4 pin A/1 and pin A/9 ,
DEU mount 2010VU4 pin A/2 and pin A/10.
- install a new DEU mount 2010VU4 AMM 23-73-48-000-001 and AMM 23-73-48-400-001
- reconnect the connector 7213VC4 to the DEU mount 2010VU4 AMM 23-73-48-400-001
- do the steps 4. B. (6) again for the subsequent DEU mounts until the maintenance message stops:
DIR-CIDS (101RH) and DEU mount 2010VU8 /connector 7213VC8,
DIR-CIDS (101RH) and DEU mount 2010VU12 /connector 7213VC12,
DIR-CIDS (101RH) and DEU mount 2010VU18 /connector 7213VC18,
DIR-CIDS (101RH) and DEU mount 2010VU22 /connector 7213VC22,
DIR-CIDS (101RH) and DEU mount 2014VU4 /connector 7253VC4.
- remove the DEU-A [200RH26] AMM 23-73-46-000-001.
- do a check for a short circuit again.
- install a new DEU-A [200RH26] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH26] AMM 23-73-46-400-001.
- diconnect the electrical connector 7253VC4 from the DEU mount 2014VU4 ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU mount 2014VU4 AMM 23-73-48-400-001,
- do the steps 4. B. (7) again for the subsequent DEUs and DEU mounts until the maintenance message stops: ASM 237306
DEU-A [200RH22] and DEU mount 2010VU22 ,
DEU-A [200RH18] and DEU mount 2010VU18 ,
DEU-A [200RH12] and DEU mount 2010VU12 ,
DEU-A [200RH8] and DEU mount 2010VU8 ,
DEU-A [200RH4] and DEU mount 2010VU4 .
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
- repaire the wiring between the related DEU mount 2010VUxx and the DEU mount 2014VUxx/2010VUxx ASM 237306.
- install a new DEU mount 2014VU4 AMM 23-73-48-400-001.
B. If the CIDS1/CIDS BUS test gives the maintenance message CIDS TOP BUS 1R/ DIR1 (101RH)
Subtask 23-73-00-810-136-K ** ON A/C NOT FOR ALL - remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
- make sure that at least one cabin door is open,
- On the overhead-panel 25VU:
make sure that the EMER EXIT LT switch (4WL) is in the OFF position, - close these CBs:
49VU: 157RH COM/CIDS/DIR ESS/2,
120VU: 156RH COM NAV/CIDS/DIR NORM /2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS, - wait for approx. 120 s,
- do the CIDS2/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH COM/CIDS/DIR ESS/2,
120VU: 156RH COM NAV/CIDS/DIR NORM /2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS, - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- do the CIDS1/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001
- open these CBs:
49VU: 158RH COM/CIDS/DEU A ESS/FWD R
49VU: 172RH COM/CIDS/DEU A ESS/AFT R
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD
121VU: 168RH COM NAV/CIDS/DEU A NORM/R AFT - make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/A15 and connector AA/B15 is between approx. 80 and 120 ohms ASM 237306.
- make sure that the resistance (line to GND) is not less than 200 ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/A15 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/B15 and GND. ASM 237306
- remove the DEU-A [200RH16] AMM 23-73-46-000-001
- install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- close these CBs:
49VU: 158RH COM/CIDS/DEU A ESS/FWD R
49VU: 172RH COM/CIDS/DEU A ESS/AFT R
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD
121VU: 168RH COM NAV/CIDS/DEU A NORM/R AFT - do the CIDS Interface and POWER-Up test through the MCDU/CFDS AMM 23-73-00-740-005.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH16] AMM 23-73-46-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEUs until the maintenance message stops: ASM 237306
DEU-A [200RH14]
DEU-A [200RH12]
DEU-A [200RH8]
DEU-A [200RH4]
DEU-A [200RH2]
- remove the DEU-A [200RH16] AMM 23-73-46-000-001
- do a check for a short circuit again.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ASM 237306
- do a check for a short circuit again.
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- remove the DEU-A [200RH14] AMM 23-73-46-000-001
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-A [200RH14] AMM 23-73-46-400-001.
- b.2. If the fault continues:
- install the removed DEU-A [200RH14] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [208RH14] ASM 237306.
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the connector between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX (208RH14) and the DEU TERMINATIONBOX (209RH2) ASM 237306.
- b.2.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX [208RH14] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- b.2.2. If there is a short circuit:
- install the removed DEU-A [200RH14] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU CONNECTION BOX [208RH14]
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: ASM 237306
DEU-A [200RH12] and DEU CONNECTION BOX [208RH12] ,
DEU-A [200RH8] and DEU CONNECTION BOX [208RH8] ,
DEU-A [200RH4] and DEU CONNECTION BOX [208RH4] ,
DEU-A [200RH2] and DEU CONNECTION BOX [208RH2] ,
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ,
- make sure that the resistance (line to line) is not more than 120 ohms (open circuit) between:
DEU TERMINATION BOX (209RH2) pin A/1 and pin A/2
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [208RH2] ,
- do a check of the wiring (continuity-check) between:
DIR-CIDS (101RH) connector AA/A15 and the connector from the DEU CONNECTION BOX [208RH2] pin A/2,
DIR-CIDS (101RH) connector AA/B15 and the connector from the DEU CONNECTION BOX [208RH2] pin A/2.
- repair the wiring between the DIR-CIDS (101RH) and the connector of the DEU CONNECTION BOX [208RH2] ASM 237306.
- do a check of the wiring (continuity-check) between:
DEU CONNECTION BOX [208RH2] pin A/1 and pin A/9 ,
DEU CONNECTION BOX [208RH2] pin A/2 and pin A/10.
- install a new DEU CONNECTION BOX [208RH2] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- reconnect the connector DEU CONNECTION BOX [208RH2] .
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION BOXES until the maintenance message stops:
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH4] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH8] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH12] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH14] ,
DIR-CIDS (101RH) and DEU TERMINATION BOX [209RH2] ,
- remove the DEU-A [200RH16] AMM 23-73-46-000-001.
- do a check for a short circuit again.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH16] AMM 23-73-46-400-001.
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- do the steps 4. B. (7) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: ASM 237306
DEU-A [200RH14] and DEU CONNECTION BOX [208RH14] ,
DEU-A [200RH12] and DEU CONNECTION BOX [208RH12] ,
DEU-A [200RH8] and DEU CONNECTION BOX [208RH8] ,
DEU-A [200RH4] and DEU CONNECTION BOX [208RH4] ,
DEU-A [200RH2] and DEU CONNECTION BOX [208RH2] ,
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
- repair the wiring between the related DEU CONNECTION BOX 208RHxx and the DEU CONNECTION/ TERMINATION BOX 208/209RHxx ASM 237306.
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
B. If the CIDS1/CIDS BUS test gives the maintenance message CIDS TOP BUS 1R/ DIR1 (101RH)
Subtask 23-73-00-810-136-O ** ON A/C NOT FOR ALL - remove the DIR-CIDS (101RH) AMM 23-73-34-000-001,
- make sure that at least one cabin door is open,
- close these CBs:
49VU: 157RH COM/CIDS/DIR ESS/2,
120VU: 156RH COM NAV/CIDS/DIR NORM /2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS, - wait for approx. 120 s,
- do the CIDS2/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 (101RH) do not close these CBs:
49VU: 157RH COM/CIDS/DIR ESS/2,
120VU: 156RH COM NAV/CIDS/DIR NORM /2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS, - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- do the CIDS1/CIDS BUS test through the MCDU/CFDS.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001
- open these CBs:
49VU: 158RH COM/CIDS/DEU A ESS/FWD R
49VU: 172RH COM/CIDS/DEU A ESS/AFT R
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD
121VU: 168RH COM NAV/CIDS/DEU A NORM/R AFT - make sure that the resistance (line to line) at DIR-CIDS (101RH) and (102RH) connector AA/A15 and connector AA/B15 is between approx. 80 and 120 ohms ASM 237306.
- make sure that the resistance (line to GND) is not less than 200 ohms (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/A15 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/B15 and GND. ASM 237306
- remove the DEU-A [200RH16] AMM 23-73-46-000-001
- install the DIR-CIDS (101RH) and DIR-CIDS (102RH) AMM 23-73-34-400-001.
- close these CBs:
49VU: 158RH COM/CIDS/DEU A ESS/FWD R
49VU: 172RH COM/CIDS/DEU A ESS/AFT R
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD
121VU: 168RH COM NAV/CIDS/DEU A NORM/R AFT - do the CIDS Interface and POWER-Up test through the MCDU/CFDS AMM 23-73-00-740-005.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH16] AMM 23-73-46-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEUs until the maintenance message stops: ASM 237306
DEU-A [200RH14]
DEU-A [200RH12]
DEU-A [200RH8]
DEU-A [200RH4]
DEU-A [200RH2]
- remove the DEU-A [200RH16] AMM 23-73-46-000-001
- do a check for a short circuit again.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ASM 237306
- do a check for a short circuit again.
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- remove the DEU-A [200RH14] AMM 23-73-46-000-001
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-A [200RH14] AMM 23-73-46-400-001.
- b.2. If the fault continues:
- install the removed DEU-A [200RH14] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [208RH14] ASM 237306.
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the connector between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX (208RH14) and the DEU TERMINATIONBOX (209RH2) ASM 237306.
- b.2.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX [208RH14] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- b.2.2. If there is a short circuit:
- install the removed DEU-A [200RH14] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU CONNECTION BOX [208RH14]
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: ASM 237306
DEU-A [200RH12] and DEU CONNECTION BOX [208RH12] ,
DEU-A [200RH8] and DEU CONNECTION BOX [208RH8] ,
DEU-A [200RH4] and DEU CONNECTION BOX [208RH4] ,
DEU-A [200RH2] and DEU CONNECTION BOX [208RH2] ,
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ,
- make sure that the resistance (line to line) is not more than 120 ohms (open circuit) between:
DEU TERMINATION BOX (209RH2) pin A/1 and pin A/2
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [208RH2] ,
- do a check of the wiring (continuity-check) between:
DIR-CIDS (101RH) connector AA/A15 and the connector from the DEU CONNECTION BOX [208RH2] pin A/2,
DIR-CIDS (101RH) connector AA/B15 and the connector from the DEU CONNECTION BOX [208RH2] pin A/2.
- repair the wiring between the DIR-CIDS (101RH) and the connector of the DEU CONNECTION BOX [208RH2] ASM 237306.
- do a check of the wiring (continuity-check) between:
DEU CONNECTION BOX [208RH2] pin A/1 and pin A/9 ,
DEU CONNECTION BOX [208RH2] pin A/2 and pin A/10.
- install a new DEU CONNECTION BOX [208RH2] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- reconnect the connector DEU CONNECTION BOX [208RH2] .
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION BOXES until the maintenance message stops:
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH4] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH8] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH12] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH14] ,
DIR-CIDS (101RH) and DEU TERMINATION BOX [209RH2] ,
- remove the DEU-A [200RH16] AMM 23-73-46-000-001.
- do a check for a short circuit again.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH16] AMM 23-73-46-400-001.
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- do the steps 4. B. (7) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: ASM 237306
DEU-A [200RH14] and DEU CONNECTION BOX [208RH14] ,
DEU-A [200RH12] and DEU CONNECTION BOX [208RH12] ,
DEU-A [200RH8] and DEU CONNECTION BOX [208RH8] ,
DEU-A [200RH4] and DEU CONNECTION BOX [208RH4] ,
DEU-A [200RH2] and DEU CONNECTION BOX [208RH2] ,
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306
- repair the wiring between the related DEU CONNECTION BOX 208RHxx and the DEU CONNECTION/ TERMINATION BOX 208/209RHxx ASM 237306.
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
B. If the CIDS Interface and Power-Up test gives the maintenance message CIDS TOP BUS 1R/DIR1 (101RH):
Subtask 23-73-00-810-464-A ** ON A/C NOT FOR ALL - remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001,
- make sure that at least one cabin door is open.
- on the overhead panel 25VU:
make sure that the EMER EXIT LT switch (4WL) is in the OFF position. - close these CBs:
49VU: 157RH COM/CIDS/DIR ESS/2,
120VU: 156RH COM NAV/CIDS/DIR NORM /2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS. - wait for approx. 120s,
- do the CIDS2 Interface and Power-Up test through the CFDS.
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
- during the installation of the DIR-CIDS, 1 [101RH] do not close these CBs:
49VU: 157RH COM/CIDS/DIR ESS/2,
120VU: 156RH COM NAV/CIDS/DIR NORM /2,
122VU: 14WH AIR COND/CIDS/SDF/DIR NORM/2,
49VU: 18WH AIR COND/CIDS/SDF/DIR 2 ESS. - install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
- do the CIDS Interface and Power-Up test through the CFDS.
- install a new DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- remove the DIR-CIDS, 1 [101RH] AMM 23-73-34-000-001.
- open these CBs:
49VU: 158RH COM/CIDS/DEU A ESS/FWD R,
49VU: 196RH COM/CIDS/DEU A ESS/MID R,
49VU: 172RH COM/CIDS/DEU A ESS/AFT R,
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD,
2001VU: 198RH COM NAV/CIDS/DEU A NORM/R MID,
2001VU: 174RH COM NAV/CIDS/DEU A NORM/R AFT. - make sure that the resistance (line to line) at DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] connector AA/A15 and connector AA/B15 is between approx. 80 and 120 ohm ASM 237306.
- make sure that the resistance (line to GND) is not less than 200 ohm (short circuit) between:
DIR-CIDS (101RH) and (102RH) connector AA/A15 and GND,
DIR-CIDS (101RH) and (102RH) connector AA/B15 and GND. ASM 237306
- remove the DEU-A [200RH16] AMM 23-73-46-000-001,
- install the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- close these CBs:
49VU: 158RH COM/CIDS/DEU A ESS/FWD R,
49VU: 196RH COM/CIDS/DEU A ESS/MID R,
49VU: 172RH COM/CIDS/DEU A ESS/AFT R,
121VU: 164RH COM NAV/CIDS/DEU A NORM/R FWD,
2001VU: 198RH COM NAV/CIDS/DEU A NORM/R MID,
2001VU: 174RH COM NAV/CIDS/DEU A NORM/R AFT. - do the CIDS Interface and Power-Up test through the CFDS.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH16] AMM 23-73-46-400-001.
- do the steps 4. B. (5) (a) again for the subsequent DEUs until the maintenance message stops: ASM 237306
DEU-A [200RH14]
DEU-A [200RH12]
DEU-A [200RH10]
DEU-A [200RH8]
DEU-A [200RH6]
DEU-A [200RH4]
DEU-A [200RH2]
- remove the DEU-A [200RH16] AMM 23-73-46-000-001,
- do a check for a short circuit again.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ASM 237306,
- do a check for a short circuit again.
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- remove the DEU-A [200RH14] AMM 23-73-46-000-001,
- do a check for a short circuit again.
- b.1. If there is no short circuit:
- install a new DEU-A [200RH14] AMM 23-73-46-400-001.
- b.2. If the fault continues:
- install the removed DEU-A [200RH14] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [208RH14] ASM 237306,
- do a check for a short circuit again.
- b.2.1. If there is no short circuit:
- do a check for a short circuit at the connector between pin 9 and GND (pin 11) and between pin 10 and GND (pin 11).
- b.2.1.1. If there is a short circuit:
- repair the wiring between the DEU CONNECTION BOX (208RH14) and the DEU TERMINATION BOX (209RH2) ASM 237306.
- b.2.1.2. If there is no short circuit:
- install a new DEU CONNECTION BOX [208RH14] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- b.2.2. If there is a short circuit:
- install the removed DEU-A [200RH14] AMM 23-73-46-400-001,
- reconnect the electrical connector to the DEU CONNECTION BOX [208RH14] ,
- do the steps (4. B. (5) (b) 2 b) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: ASM 237306
DEU-A [200RH12] and DEU CONNECTION BOX [208RH12] ,
DEU-A [200RH10] and DEU CONNECTION BOX [208RH10] ,
DEU-A [200RH8] and DEU CONNECTION BOX [208RH8] ,
DEU-A [200RH6] and DEU CONNECTION BOX [208RH6] ,
DEU-A [200RH4] and DEU CONNECTION BOX [208RH4] ,
DEU-A [200RH2] and DEU CONNECTION BOX [208RH2] .
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ,
- make sure that the resistance (line to line) is not more than 120 ohm (open circuit) between:
DEU TERMINATION BOX (209RH2) pin A/1 and pin A/2
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- disconnect the electrical connector from the DEU CONNECTION BOX [208RH2] ,
- do a check of the wiring (continuity-check) between:
DIR-CIDS (101RH) connector AA/A15 and the connector from the DEU CONNECTION BOX [208RH2] pin A/2,
DIR-CIDS (101RH) connector AA/B15 and the connector from the DEU CONNECTION BOX [208RH2] pin A/2.
- repair the wiring between the DIR-CIDS (101RH) and the connector of the DEU CONNECTION BOX [208RH2] ASM 237306.
- do a check of the wiring (continuity-check) between:
DEU CONNECTION BOX [208RH2] pin A/1 and pin A/9 ,
DEU CONNECTION BOX [208RH2] pin A/2 and pin A/10.
- install a new DEU CONNECTION BOX [208RH2] AMM 23-73-42-000-001 and AMM 23-73-42-400-001.
- reconnect the connector DEU CONNECTION BOX [208RH2] .
- do the steps 4. B. (6) again for the subsequent DEU CONNECTION BOXES until the maintenance message stops:
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH4] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH6] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH8] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH10] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH12] ,
DIR-CIDS (101RH) and DEU CONNECTION BOX [208RH14] ,
DIR-CIDS (101RH) and DEU TERMINATION BOX [209RH2] .
- remove the DEU-A [200RH16] AMM 23-73-46-000-001,
- do a check for a short circuit again.
- install a new DEU-A [200RH16] AMM 23-73-46-400-001.
- install the removed DEU-A [200RH16] AMM 23-73-46-400-001,
- disconnect the electrical connector from the DEU TERMINATION BOX [209RH2] ASM 237306,
- do a check for a short circuit again.
- reconnect the electrical connector to the DEU TERMINATION BOX [209RH2] ,
- do the steps 4. B. (7) again for the subsequent DEUs and DEU CONNECTION BOXES until the maintenance message stops: ASM 237306
DEU-A [200RH14] and DEU CONNECTION BOX [208RH14] ,
DEU-A [200RH12] and DEU CONNECTION BOX [208RH12] ,
DEU-A [200RH10] and DEU CONNECTION BOX [208RH10] ,
DEU-A [200RH8] and DEU CONNECTION BOX [208RH8] ,
DEU-A [200RH6] and DEU CONNECTION BOX [208RH6] ,
DEU-A [200RH4] and DEU CONNECTION BOX [208RH4] ,
DEU-A [200RH2] and DEU CONNECTION BOX [208RH2] .
- do a check for a short circuit at the disconnected connector between the pins A/9 and A/10 ASM 237306.
- repair the wiring between the related DEU CONNECTION BOX 208RHxx and the DEU CONNECTION/ TERMINATION BOX 208/209RHxx ASM 237306.
- install a new DEU TERMINATION BOX [209RH2] AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
C. Installation of removed components
Subtask 23-73-00-810-464-B ** ON A/C NOT FOR ALL - Install the removed DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Install all the removed DEU-A (200RHxx) AMM 23-73-46-400-001.
- Reconnect all the DEU-mount-connectors to the related DEU-mounts (2010VUxx/2014VUx) AMM 23-73-48-400-001.
C. Installation of removed components
Subtask 23-73-00-810-465-A - Install the removed DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-400-001.
- Install all the removed DEU-A (200RHxx) AMM 23-73-46-400-001.
- Reconnect all the DEU CONNECTION/ TERMINATION BOX-connectors to the related DEU CONNECTION/ TERMINATION BOX (208RHxx/209RHxx) ASM 237306
- Make sure that all previously opened CBs are closed.
D. Do the test given in Para. 3.A.