W DOC AIRBUS | TSM A320F

DEU-A - Fault in DEU-A 200RHxx with connected systems/devices


TASK 23-73-00-810-801-A
DEU-A - Fault in DEU-A 200RHxx with connected systems/devices


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DEU-A (200RHxx)
  • DEU mount 2010VUxx
  • wiring
  • Connection Box 208RHxx
  • Termination Box 209RHxx
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 23-73-00-810-943-A
PISA unit fault
TSM TASK 23-73-00-810-971-A
PCU unit fault
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
ASM 237306
ASM 237307
ASM 237308
AMM 23-73-34-400-001
Installation of the CIDS Director
AMM 23-73-42-000-001
Removal of the Connection Box (208RH,308RH)
AMM 23-73-42-400-001
Installation of the Connection Box (208RH,308RH)
AMM 23-73-43-000-001
Removal of the Termination Box (209RH,309RH)
AMM 23-73-43-400-001
Installation of the Termination Box (209RH,309RH)
AMM 23-73-46-000-001
Removal of the Decoder/Encoder Unit A (200RH)
AMM 23-73-46-400-001
Installation of the Decoder/Encoder Unit A (200RH)
AMM 23-73-48-000-001
Removal of the DEU A/DEU B - Mount
AMM 23-73-48-400-001
Installation of the DEU A/DEU B - Mount
3. Fault Confirmation
Subtask 23-73-00-710-050-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS/DEU-A test through the CFDS (via CIDS1).
Subtask 23-73-00-710-050-B ** ON A/C NOT FOR ALL
A. Test
   (1) Do the CIDS Interface and Power-Up test through the CFDS.
AMM 23-73-00-740-005
4. Fault Isolation
Subtask 23-73-00-810-050-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-789-A ** ON A/C NOT FOR ALL
B. If the test gives the "DEU A fault" message again and again, refer "PCU unit fault"
(Ref. TSM TASK 23-73-00-810-971)
Subtask 23-73-00-810-789-B ** ON A/C NOT FOR ALL
B. If the test gives the "DEU A fault" message again and again, refer "PISA unit fault"
(Ref. TSM TASK 23-73-00-810-943)
Subtask 23-73-00-810-102-D ** ON A/C NOT FOR ALL
C. If the CIDS1/DEU-A test gives the maintenance message DEU-A 200RHxx:
  • make sure that at least one cabin door is open,
  • make sure that the EMER LT (4WL) switch is in the OFF position,
  • open these CBs:
    49VU: 150RH (G01) COM DIR ESS/1
    49VU: 157RH (G02) COM DIR ESS/2
    121VU:151RH (M06) CIDS/DIR NORM/1,
    121VU:156RH (M07) CIDS/DIR NORM/2,
  • wait for approx. 10 s and close the CBs 156RH and 157RH,
  • stop for approx. 120 s,
  • do the CIDS/DEU-A test (via CIDS2).
   (1) If the CIDS2/DEU-A test is OK:
   (2) If the fault continues:
     (a) If the coding switch position(s) is (are) not correct:
  • make an adjustment of the related coding switch(es).
     (b) If the coding switch position(s) is (are) correct:
       1 If the fault continues:
         a If the fault continues:
  • do a check for
    28VDC at DEU mount 2010VUxx connector A/8,
    28VDC at DEU mount 2010VUxx connector A/5,
    GND at DEU mount 2010VUxx connector A/7,
    ASM 237306, ASM 237307 and ASM 237308
    and repair the wiring if necessary.
Subtask 23-73-00-810-102-F ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) If the coding switch position(s) is (are) not correct:
  • make an adjustment of the related coding switch(es).
   (2) If the coding switch position(s) is (are) correct:
     (a) If the fault continues:
       1 If the fault continues:
  • do a check for 28VDC at the related Connection Box 208RHxx or Termination Box 209RHxx connector A/8,
    connector A/5 and connector A/8,
    and
    GND signal at connector A/7,
    ASM 237306, ASM 237307 and ASM 237308
    and repair the wiring if necessary.
Subtask 23-73-00-810-494-A ** ON A/C NOT FOR ALL
D. Install the removed DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
Subtask 23-73-00-710-188-A
E. Do the test given in Para. 3.A.