DEU-A - Fault in DEU-A 200RHxx with connected systems/devices
TASK 23-73-00-810-801-A
DEU-A - Fault in DEU-A 200RHxx with connected systems/devices
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-73-00-710-050-A ** ON A/C NOT FOR ALL
Subtask 23-73-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:49 UTC
DEU-A - Fault in DEU-A 200RHxx with connected systems/devices
1. Possible Causes
- DIR-CIDS, 1 [101RH]
DEU-A (200RHxx) - DEU mount 2010VUxx
- wiring
- Connection Box 208RHxx
- Termination Box 209RHxx
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 23-73-00-810-943-A | PISA unit fault |
| TSM TASK 23-73-00-810-971-A | PCU unit fault |
| AMM 23-73-00-740-005 | BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS |
| ASM 237306 | |
| ASM 237307 | |
| ASM 237308 | |
| AMM 23-73-34-400-001 | Installation of the CIDS Director |
| AMM 23-73-42-000-001 | Removal of the Connection Box (208RH,308RH) |
| AMM 23-73-42-400-001 | Installation of the Connection Box (208RH,308RH) |
| AMM 23-73-43-000-001 | Removal of the Termination Box (209RH,309RH) |
| AMM 23-73-43-400-001 | Installation of the Termination Box (209RH,309RH) |
| AMM 23-73-46-000-001 | Removal of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-46-400-001 | Installation of the Decoder/Encoder Unit A (200RH) |
| AMM 23-73-48-000-001 | Removal of the DEU A/DEU B - Mount |
| AMM 23-73-48-400-001 | Installation of the DEU A/DEU B - Mount |
Subtask 23-73-00-710-050-A ** ON A/C NOT FOR ALL
A. Test
(1) Do the CIDS/DEU-A test through the CFDS (via CIDS1).
Subtask 23-73-00-710-050-B ** ON A/C NOT FOR ALL 4. Fault Isolation(1) Do the CIDS/DEU-A test through the CFDS (via CIDS1).
Subtask 23-73-00-810-050-A
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-73-00-810-789-A ** ON A/C NOT FOR ALL B. If the test gives the "DEU A fault" message again and again, refer "PCU unit fault"
(Ref. TSM TASK 23-73-00-810-971)
Subtask 23-73-00-810-789-B ** ON A/C NOT FOR ALL (Ref. TSM TASK 23-73-00-810-971)
B. If the test gives the "DEU A fault" message again and again, refer "PISA unit fault"
(Ref. TSM TASK 23-73-00-810-943)
Subtask 23-73-00-810-102-D ** ON A/C NOT FOR ALL (Ref. TSM TASK 23-73-00-810-943)
C. If the CIDS1/DEU-A test gives the maintenance message DEU-A 200RHxx:
Subtask 23-73-00-810-102-F ** ON A/C NOT FOR ALL - make sure that at least one cabin door is open,
- make sure that the EMER LT (4WL) switch is in the OFF position,
- open these CBs:
49VU: 150RH (G01) COM DIR ESS/1
49VU: 157RH (G02) COM DIR ESS/2
121VU:151RH (M06) CIDS/DIR NORM/1,
121VU:156RH (M07) CIDS/DIR NORM/2, - wait for approx. 10 s and close the CBs 156RH and 157RH,
- stop for approx. 120 s,
- do the CIDS/DEU-A test (via CIDS2).
- install a new DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001
- make sure that the related coding switch(es) is (are) set to the correct DEU-A address ASM 237306, ASM 237307 and ASM 237308.
- make an adjustment of the related coding switch(es).
- replace the
DEU-A (200RHxx) AMM 23-73-46-000-001 and AMM 23-73-46-400-001.
- replace the DEU mount 2010VUxx AMM 23-73-48-000-001 and AMM 23-73-48-400-001.
- do a check for
28VDC at DEU mount 2010VUxx connector A/8,
28VDC at DEU mount 2010VUxx connector A/5,
GND at DEU mount 2010VUxx connector A/7,
ASM 237306, ASM 237307 and ASM 237308
and repair the wiring if necessary.
C. If the fault continues:
Subtask 23-73-00-810-494-A ** ON A/C NOT FOR ALL Subtask 23-73-00-710-188-A - make sure that the related coding switch(es) is (are) set to the correct DEU-A address ASM 237306, ASM 237307 and ASM 237308.
- make an adjustment of the related coding switch(es).
- replace the
DEU-A (200RHxx) AMM 23-73-46-000-001 and AMM 23-73-46-400-001.
- replace the related Connection Box 208RHxx AMM 23-73-42-000-001 and AMM 23-73-42-400-001 or Termination Box 209RHxx AMM 23-73-43-000-001 and AMM 23-73-43-400-001.
- do a check for 28VDC at the related Connection Box 208RHxx or Termination Box 209RHxx connector A/8,
connector A/5 and connector A/8,
and
GND signal at connector A/7,
ASM 237306, ASM 237307 and ASM 237308
and repair the wiring if necessary.
E. Do the test given in Para. 3.A.