W DOC AIRBUS | TSM A320F

Camera 3 Failure


TASK 23-72-00-810-806-A
Camera 3 Failure


1. Possible Causes
  • CAMERA- DR 1, LH [13RA]
  • MONITOR- COCKPIT DOOR SURVEILLANCE SYSTEM [10RA]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-72-00-710-001
Operational Test of the Anti-Hijack Camera-Monitoring-System
ASM 237201
AMM 23-72-22-000-001
Removal of the Cockpit-Door Surveillance-System Monitor
AMM 23-72-22-400-001
Installation of the Cockpit-Door Surveillance-System Monitor
AMM 23-72-51-000-001
Removal of the Anti-Hijack-System Cameras
AMM 23-72-51-400-001
Installation of the Anti-Hijack-System Cameras
3. Fault Confirmation
Subtask 23-72-00-710-054-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the operational test of the Cockpit Door Surveillance System (CDSS) AMM 23-72-00-710-001.
4. Fault Isolation
Subtask 23-72-00-810-064-A ** ON A/C NOT FOR ALL
A. If the images from cameras 1 and 2 are good and the images from camera 3 are bad, and the green LED is on:
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and if necessary repair the wiring between the MONITOR- COCKPIT DOOR SURVEILLANCE SYSTEM [10RA] and the CAMERA- DR 1, LH [13RA] , ASM 237201.
Subtask 23-72-00-700-054-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:48 UTC