Recording on All the Channels Inoperative


TASK 23-71-00-810-805-A
Recording on All the Channels Inoperative


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-71-00-710-001
Operational Test of the CVR and the CVR Channel Recording
ASM 237101
AMM 23-71-35-000-001
Removal of the Cockpit Voice Recorder (CVR) 1RK
AMM 23-71-35-400-001
Installation of the Cockpit Voice Recorder (CVR) 1RK
3. Fault Confirmation
Subtask 23-71-00-710-058-A
A. Test
   (1) Do the operational test of the CVR and the CVR channel recording AMM 23-71-00-710-001.
4. Fault Isolation
Subtask 23-71-00-865-050-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/CVR/SPLY2RKE14
** ON A/C NOT FOR ALL
49VUCOM/CVR/SPLY23RKE14
49VUCOM/CVR/CTL26RKE13
Subtask 23-71-00-810-054-A ** ON A/C NOT FOR ALL
B. If during the operational test the recording is inoperative:
  • push the MON. IND. FOR GND/CTL pushbutton switch (11TU) on the panel 21VU.
   (1) If it comes on and the fault continues:
     (a) If the fault continues:
  • do a check of the circuit breaker (2RK) status.
       1 If the circuit breaker is closed:
  • do a check for a ground signal at pin 3 of the CVR (1RK) ASM 237101.
         a If there is no ground signal:
  • repair the wiring from CVR (1RK) pin A/3 to the first terminal block ASM 237101.
         b If there is a ground signal:
  • do a check of the wiring from the C/B (2RK) to the first terminal block and of the relay (8RK) ASM 237101.
    . If there is no continuity:
    * repair the above wiring.
    . If there is continuity:
    * replace the C/B-COM/CVR/SPLY [2RK] .
       2 If the circuit breaker is open:
  • close it.
         a If it opens again:
  • replace the C/B-COM/CVR/SPLY [2RK] .
         b If it opens again:
  • do a check for a short to ground and repair the wiring of the system ASM 237101.
   (2) If it does not come on:
  • do a check of the circuit breaker (4RK) status.
     (a) If the circuit breaker is closed:
  • do a check of the wiring located downstream of the circuit breaker (4RK) ASM 237101.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • replace the C/B-COM/CVR/CTL [4RK] .
     (b) If the circuit breaker is open:
  • close it.
       1 If it opens again:
  • replace the C/B-COM/CVR/CTL [4RK] .
       2 If it opens again:
  • do a check for a short to ground and repair the wiring located downstream of the circuit breaker (4RK) ASM 237101.
Subtask 23-71-00-810-054-B ** ON A/C NOT FOR ALL
B. If during the operational test the recording is inoperative:
  • push the MON. IND. FOR GND/CTL pushbutton switch (11TU) on the panel 21VU.
   (1) If it comes on and the fault continues:
     (a) If the fault continues:
  • do a check of the circuit breaker (23RK) status.
       1 If the circuit breaker is closed:
  • do a check for a ground signal at pin 3 of the CVR (1RK) ASM 237101.
         a If there is no ground signal:
  • repair the wiring from CVR (1RK) pin A/3 to the first terminal block ASM 237101.
         b If there is a ground signal:
  • do a check of the wiring from the C/B (23RK) to the first terminal block and of the relay (8RK) ASM 237101.
    . If there is no continuity:
    * repair the above wiring.
    . If there is continuity:
    * replace the C/B [23RK] .
       2 If the circuit breaker is open:
  • close it.
         a If it opens again:
  • replace the C/B [23RK] .
         b If it opens again:
  • do a check for a short to ground and repair the wiring of the system ASM 237101.
   (2) If it does not come on:
  • do a check of the circuit breaker (26RK) status.
     (a) If the circuit breaker is closed:
  • do a check of the wiring located downstream of the circuit breaker (26RK) ASM 237101.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • replace the C/B [26RK] .
     (b) If the circuit breaker is open:
  • close it.
       1 If it opens again:
  • replace the C/B [26RK] .
       2 If it opens again:
  • do a check for a short to ground and repair the wiring located downstream of the circuit breaker (26RK) ASM 237101.
Subtask 23-71-00-710-059-A
C. Do te test given in Para. 3.