Loss of the SELCAL Code
TASK 23-51-00-810-828-A
Loss of the SELCAL Code
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-51-00-710-060-A
Subtask 23-51-00-810-077-A
[Rev.8 from Aug 2018]
2026.04.04 04:38:57 UTC
Loss of the SELCAL Code
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-51-00-710-002 | Operational Test of the SELCAL System |
| AMM 23-51-00-820-801 | Adjustment of the SELCAL Code |
| ASM 235106 | |
| AMM 23-51-13-000-001 | Removal of the SELCAL Code Panel |
| AMM 23-51-13-400-001 | Installation of the SELCAL Code Panel |
| AMM 23-51-34-000-001 | Removal of the Audio Management Unit (AMU) (1RN) |
| AMM 23-51-34-400-001 | Installation of the Audio Management Unit (AMU) (1RN) |
Subtask 23-51-00-710-060-A
A. Test
(1) Do the operational test of the SELCAL system AMM 23-51-00-710-002.
4. Fault Isolation(1) Do the operational test of the SELCAL system AMM 23-51-00-710-002.
NOTE: Do this test for each HF (if installed) and VHF system.
Subtask 23-51-00-810-077-A
A. If the ground station cannot make a SELCAL call during the operational test of each HF (if installed) and VHF system:
Subtask 23-51-00-710-061-A - Make sure that the code of the SELCAL CODE PNL [3RN] is the same as the code transmitted to the ground station AMM 23-51-00-820-801.
- Replace the AMU [1RN] AMM 23-51-34-000-001 and AMM 23-51-34-400-001.
- Replace the SELCAL CODE PNL [3RN] AMM 23-51-13-000-001 and AMM 23-51-13-400-001.
- Do a check and repair the wiring between the SELCAL CODE PNL [3RN] and the AMU [1RN] ASM 235106.
B. Do the test given in Para. 3.