Failure of the Fourth Occupant ACP
TASK 23-51-00-810-805-A
Failure of the Fourth Occupant ACP
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-51-00-740-058-A 4. Fault Isolation
Subtask 23-51-00-810-054-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:43 UTC
Failure of the Fourth Occupant ACP
1. Possible Causes
[2RN5] - wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-51-00-740-002 | BITE Test of the Audio System |
| ASM 235108 | |
| AMM 23-51-12-000-001 | Removal of the Audio Control Panel (ACP) (2RN1, 2RN2, 2RN3, 2RN4, 2RN5) |
| AMM 23-51-12-400-001 | Installation of the Audio Control Panel (ACP) (2RN1, 2RN2, 2RN3, 2RN4, 2RN5) |
Subtask 23-51-00-740-058-A 4. Fault Isolation
Subtask 23-51-00-810-054-B
A. If the test gives the maintenance message ACP5(2RN5):
- Do a check for 28VDC at pin A/M of the
[2RN5] ASM 235108.
- Replace the
[2RN5] AMM 23-51-12-000-001 and AMM 23-51-12-400-001.
- Do a check for a ground signal at pin A/N of the
[2RN5] ASM 235108.
- Repair the wiring from the
[2RN5] pin A/N to the ground terminal ASM 235108.
- Do a check and repair the wiring from the
[2RN5] pin A/M to the first terminal block ASM 235108.