Failure of the Avionics Compartment ACP
TASK 23-51-00-810-804-A
Failure of the Avionics Compartment ACP
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-51-00-740-056-A 4. Fault Isolation
Subtask 23-51-00-810-053-D
[Rev.8 from Aug 2018]
2026.04.04 04:25:43 UTC
Failure of the Avionics Compartment ACP
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-51-00-740-002 | BITE Test of the Audio System |
| ASM 235105 | |
| AMM 23-51-12-000-001 | Removal of the Audio Control Panel (ACP) (2RN1, 2RN2, 2RN3, 2RN4, 2RN5) |
| AMM 23-51-12-400-001 | Installation of the Audio Control Panel (ACP) (2RN1, 2RN2, 2RN3, 2RN4, 2RN5) |
Subtask 23-51-00-740-056-A 4. Fault Isolation
Subtask 23-51-00-810-053-D
A. If the test gives the maintenance message ACP4(2RN4):
Subtask 23-51-00-740-057-A - Do a check for 28VDC at pin A/M of the
[2RN4] ASM 235105.
- Replace the
[2RN4] AMM 23-51-12-000-001 and AMM 23-51-12-400-001.
- Do a check and repair the wiring from:
. The AMU [1RN] pin A/M to the circuit breaker C/B-COM NAV/ACP/AVNCS/COMPT [7RN] .
. The AMU [1RN] pin A/N to the ground terminal ASM 235105.
B. Do the test given in Para. 3.