W DOC AIRBUS | TSM A320F

Loss of Service Interphone data at the director


TASK 23-44-00-810-806-A
Loss of Service Interphone data at the director


1. Possible Causes
  • DIR-CIDS, 1 [101RH]
  • DIR-CIDS, 2 [102RH]
  • MAINTENANCE INTERPHONE JACK
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AWM 234402
AWM 234403
AMM 23-44-41-000-002
Removal of the Jack - Maintenance Interphone
AMM 23-44-41-000-003
Removal of the Maintenance Interphone Jack
AMM 23-44-41-400-002
Installation of the Jack - Maintenance Interphone
AMM 23-44-41-400-003
Installation of the Maintenance Interphone Jack
AMM 23-73-00-040-001
Deactivation of the CIDS Director
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-34-000-001
Removal of the CIDS Director
AMM 23-73-34-400-001
Installation of the CIDS Director
3. Fault Confirmation
Subtask 23-44-00-740-051-A ** ON A/C NOT FOR ALL
A. Do the BITE-test of the Cabin Intercommunication Data-System (CIDS) AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-44-00-810-053-A ** ON A/C NOT FOR ALL
A. If the test confirms the fault:
   (1) Deactivate the related DIR-CIDS, 1 [101RH] or DIR-CIDS, 2 [102RH] AMM 23-73-00-040-001.
   (2) Do the test given in Para. 3.
     (a) If the test is OK:
Replace the related DIR-CIDS AMM 23-73-34-000-001 and AMM 23-73-34-400-001.
     (b) If the test is not OK:
Remove the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AMM 23-73-34-000-001.
   (3) On the rack, do a check for a short to ground at the DIR-CIDS, 1 [101RH] and DIR-CIDS, 2 [102RH] AWM 234402 AWM 234403.
     (a) If there is no short to ground:
       1 Install the DIR-CIDS, 1 [101RH] AMM 23-73-34-400-001.
       2 Do the test given in Para. 3.
       3 If the test is OK:
  • Install a new DIR-CIDS, 2 [102RH] .
       4 If the test is not OK:
     (b) If there is a short to ground:
       1 Disconnect the electrical connector of one MAINTENANCE INTERPHONE JACK in the cabin.
       2 Do a check for a short circuit at the connector of the interphone jack.
       3 If there is a short circuit:
  • Replace the interphone jack.
       4 If there is no short circuit:
  • Do the steps 1_ thru 4_ again until you have tested all the interphone jacks in the cabin.
       5 If the fault continues:
       6 Disconnect the electrical connector of one interphone jack in the power plant.
       7 Do a check for a short circuit at the connector of the interphone jack.
       8 If there is a short circuit:
       9 If there is no short circuit:
  • Do the steps 6_ thru 9_ again until you have tested all the interphone jacks in the power plant.
       10 If the fault continues:
       11 Do a check of the wiring for a short to ground of the MIC HI IN and the AUDIO HI OUT signal from:
  • The DIR-CIDS, 1 [101RH] to DIR-CIDS, 2 [102RH]
  • The DIR-CIDS, 1 [101RH] to all interphone jacks
  • The DIR-CIDS, 2 [102RH] to all interphone jacks.
AWM 234402 AWM 234403
       12 Repair the wiring as necessary.
       13 Install the removed DIR-CIDS AMM 23-73-34-400-001.
5. Close-up
Subtask 23-44-00-740-052-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:43 UTC