Fault of the PRAM Card


TASK 23-32-00-810-804-A
Fault of the PRAM Card


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-32-36-000-001
Removal of the Integrated PRAM Flashcard
AMM 23-32-36-400-001
Installation of the Integrated PRAM Flashcard
AMM 23-73-00-740-005
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
AMM 23-73-12-000-007
Removal of the Flight Attendant Panel
AMM 23-73-12-400-007
Installation of the Flight Attendant Panel
3. Fault Confirmation
Subtask 23-32-00-710-054-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the interface and power-up test of the CIDS AMM 23-73-00-740-005.
4. Fault Isolation
Subtask 23-32-00-810-057-A ** ON A/C NOT FOR ALL
A. If the test gives a different maintenance message, do the trouble shooting procedure related to the maintenance message.
Subtask 23-32-00-810-058-A ** ON A/C NOT FOR ALL
B. If the test confirms the fault, do the trouble shooting that follows.
   (1) If the test gives the maintenance message PRAM CARD(117RH):
     (a) Install the I-PRAM, CF-CARD [117RH] , AMM 23-32-36-000-001 and AMM 23-32-36-400-001.
Subtask 23-32-00-810-061-A ** ON A/C NOT FOR ALL
C. If the fault continues:
   (1) Replace the FAP [120RH] , AMM 23-73-12-000-007 and AMM 23-73-12-400-007.
5. Close-up
Subtask 23-32-00-710-055-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.