W DOC AIRBUS | TSM A320F

Loss of the RMP1 and RMP2 Displays


TASK 23-13-00-810-864-A
Loss of the RMP1 and RMP2 Displays


1. Possible Causes
  • RMP-COM/NAV FREQ SEL, 1 [1RG1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
ASM 238101
ASM 238102
3. Fault Confirmation
Subtask 23-13-00-710-057-A
A. Test
   (1) Make sure that the circuit breakers (2RG1) and (2RG2) are closed.
   (2) On RMP1 (1RG1) and RMP2 (1RG2), make sure that the ON/OFF switches are set to ON.
   (3) Make sure that the RMP1 (1RG1) and RMP2 (1RG2) displays are defective.
4. Fault Isolation
Subtask 23-13-00-810-102-A
A. If the test confirms the fault:
  • On RMP1 (1RG1) and RMP2 (1RG2), set the ON/OFF switches to OFF.
  • Open the circuit breakers (2RG1) and (2RG2) and wait for 5 seconds.
  • Close the circuit breaker (2RG1).
  • On RMP1 (1RG1), set the ON/OFF switch to ON.
   (1) If the RMP1 (1RG1) displays are defective:
  • Remove RMP1 (1RG1) AMM 23-13-13-000-001.
  • Close the circuit breaker (2RG2).
  • On RMP2 (1RG2), set the ON/OFF switch to ON.
   (2) If the RMP2 (1RG2) displays are on:
   (3) If the RMP1 (1RG1) displays are defective:
  • Remove RMP1 (1RG1) AMM 23-13-13-000-001.
  • Do a check and repair the wiring for a short to ground at RMP1 (1RG1) pin <R ASM 238102.
  • Do a check and repair the wiring for a short to ground at RMP1 (1RG1) pin <S ASM 238102.
  • Do a check and repair the wiring for a short to ground at RMP1 (1RG1) pin <P ASM 238101.
  • Do a check and repair the wiring for a short to ground at RMP1 (1RG1) pin <Q ASM 238102.
  • Install RMP1 (1RG1) AMM 23-13-13-400-001.
Subtask 23-13-00-710-059-A
B. Do the test given in Para. 3.
5. Close-up
Subtask 23-13-00-860-090-A
A. Put the aircraft back to its initial configuration.
[Rev.8 from Aug 2018] 2026.04.04 04:25:41 UTC