LGCIU2/RMP3 interface fault
TASK 23-13-00-810-858-A
LGCIU2/RMP3 interface fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-740-138-A
Subtask 23-13-00-810-097-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:41 UTC
LGCIU2/RMP3 interface fault
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 231300 | |
| AMM 23-13-00-740-001 | BITE Test of the Radio Management |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 23-13-00-740-138-A
A. Test
(1) Do the BITE test of the RMP AMM 23-13-00-740-001.
4. Fault Isolation(1) Do the BITE test of the RMP AMM 23-13-00-740-001.
NOTE: If the BITE test of the RMP passes, i.e. if the test result is OK, the RMP is operational, therefore should not be removed. Refer to TFU 23.13.00.023.
Subtask 23-13-00-810-097-A
A. If the test gives the maintenance message LGCIU1(5GA1)/RMP1(1RG1):
- Replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- Replace the
[1RG3] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- Remove the LGCIU-2 [5GA2] AMM 32-31-71-000-001
- Remove the
[1RG3] AMM 23-13-13-000-001 - Do a check and repair the wiring of the GROUND AIR DISCRET INPUT signal from AB/9C of the LGCIU2 to pin A/<E of the RMP3 ASM 231300.
- Install the
[1RG3] AMM 23-13-13-400-001. - Install the LGCIU-2 [5GA2] AMM 32-31-71-400-001.