Failure of the RMP 1
TASK 23-13-00-810-852-A
Failure of the RMP 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-860-085-A
Subtask 23-13-00-810-091-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:41 UTC
Failure of the RMP 1
1. Possible Causes
- RMP-COM/NAV FREQ SEL, 1 [1RG1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-13-00-740-001 | BITE Test of the Radio Management |
| ASM 231301 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
Subtask 23-13-00-860-085-A
A. Job Set-Up
On the RMP 1 and RMP 2 only, make sure that the ON/OFF switches are at ON.
Subtask 23-13-00-740-126-A On the RMP 1 and RMP 2 only, make sure that the ON/OFF switches are at ON.
B. Test
Do the BITE test of the Radio Management AMM 23-13-00-740-001.
4. Fault IsolationDo the BITE test of the Radio Management AMM 23-13-00-740-001.
NOTE: Do this test for the RMP 1 and RMP 2.
Subtask 23-13-00-810-091-B
A. If the tests give the two maintenance messages
RMP1(1RG1)
RMP1(1RG1)/RMP2(1RG2):
Subtask 23-13-00-740-127-A RMP1(1RG1)
RMP1(1RG1)/RMP2(1RG2):
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the wiring between the RMP1 pin A/N and the circuit breaker 1RG1 ASM 231301.
B. Do the tests given in Para. 3.B.