W DOC AIRBUS | TSM A320F

Loss of the BUS 1 Data from the CFDIU to the RMP 1


TASK 23-13-00-810-847-A
Loss of the BUS 1 Data from the CFDIU to the RMP 1


1. Possible Causes
  • RMP-COM/NAV FREQ SEL, 1 [1RG1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-13-00-740-001
BITE Test of the Radio Management
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
ASM 313202
3. Fault Confirmation
Subtask 23-13-00-865-063-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCFDS/CFDIU/SPLY2TWJ18
121VUCFDS/CFDIU/BACK/UP8TWJ17
Subtask 23-13-00-740-120-A
B. Test
Do the BITE test of the Radio Management AMM 23-13-00-740-001.
NOTE: Do this test for the RMP 1 only.
4. Fault Isolation
Subtask 23-13-00-810-088-B
A. If the test gives the maintenance message CFDIU(1TW)/RMP1(1RG1):
   (1) If the fault continues:
  • do a check and repair the wiring of the BUS 1 OUTPUT signal, (from RMP 1 (1RG1) pins A/A, B to the first terminal block) ASM 313202.
Subtask 23-13-00-740-121-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:25:40 UTC