Loss of the BUS 1 Data from the CFDIU to the RMP 1
TASK 23-13-00-810-847-A
Loss of the BUS 1 Data from the CFDIU to the RMP 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-865-063-A
Subtask 23-13-00-810-088-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:40 UTC
Loss of the BUS 1 Data from the CFDIU to the RMP 1
1. Possible Causes
- RMP-COM/NAV FREQ SEL, 1 [1RG1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-13-00-740-001 | BITE Test of the Radio Management |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
| ASM 313202 |
Subtask 23-13-00-865-063-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-13-00-740-120-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
B. Test
Do the BITE test of the Radio Management AMM 23-13-00-740-001.
4. Fault IsolationDo the BITE test of the Radio Management AMM 23-13-00-740-001.
NOTE: Do this test for the RMP 1 only.
Subtask 23-13-00-810-088-B
A. If the test gives the maintenance message CFDIU(1TW)/RMP1(1RG1):
Subtask 23-13-00-740-121-A - replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the wiring of the BUS 1 OUTPUT signal, (from RMP 1 (1RG1) pins A/A, B to the first terminal block) ASM 313202.
B. Do the test given in Para. 3.B.