Loss of the RMP 1 Data on the Bus 2 (CFDIU Source)
TASK 23-13-00-810-846-A
Loss of the RMP 1 Data on the Bus 2 (CFDIU Source)
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-865-062-A
Subtask 23-13-00-810-087-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:40 UTC
Loss of the RMP 1 Data on the Bus 2 (CFDIU Source)
1. Possible Causes
- RMP-COM/NAV FREQ SEL, 1 [1RG1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 231302 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
Subtask 23-13-00-865-062-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-13-00-860-084-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | COM/RMP/1 | 2RG1 | G10 |
B. Job Set-up
On the RMP 1 only, make sure that the ON/OFF switch is at ON.
Subtask 23-13-00-740-118-A 4. Fault IsolationOn the RMP 1 only, make sure that the ON/OFF switch is at ON.
Subtask 23-13-00-810-087-A
A. If the test gives the maintenance message NO RMP 1 DATA:
Subtask 23-13-00-740-119-A - replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the wiring of the COM 1 DATA OUTPUT signal, (from RMP 1 (1RG1) pins A/<P, <Q to the first terminal block) ASM 231302.
B. Do the test given in Para. 3.C.