Loss of the Tuning Data for the HF 1 System
TASK 23-13-00-810-811-A
Loss of the Tuning Data for the HF 1 System
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-865-056-A
Subtask 23-13-00-810-060-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:25:40 UTC
Loss of the Tuning Data for the HF 1 System
1. Possible Causes
- XCVR-HF, 1 [3RE1]
- RMP-COM/NAV FREQ SEL, 1 [1RG1]
wiring from HF 1 transceiver (3RE1) to RMP 1 (1RG1) wiring (from the HF1 transceiver (3RE1) to the RMP1 (1RG1))
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-11-00-740-001 | BITE Test of the HF System |
| AMM 23-11-33-000-001 | Removal of the HF Transceiver |
| AMM 23-11-33-400-001 | Installation of the HF Transceiver |
| ASM 231302 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
Subtask 23-13-00-865-056-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-13-00-860-060-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | COM/RMP/1 | 2RG1 | G10 |
B. Job Set-up
On the RMP 1 only, make sure that the ON/OFF switch is at ON.
Subtask 23-13-00-740-070-A On the RMP 1 only, make sure that the ON/OFF switch is at ON.
C. Test
(1) Do the BITE test of the HF system AMM 23-11-00-740-001.
4. Fault Isolation(1) Do the BITE test of the HF system AMM 23-11-00-740-001.
NOTE: Do this test for the HF 1 only.
Subtask 23-13-00-810-060-A ** ON A/C NOT FOR ALL
A. If the BITE test gives the maintenance message HF 1 : NO DATA FROM CONTROL SOURCE:
Subtask 23-13-00-810-060-C ** ON A/C NOT FOR ALL - replace the XCVR-HF, 1 [3RE1] AMM 23-11-33-000-001 and AMM 23-11-33-400-001.
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring from HF 1 transceiver (3RE1) to RMP 1 (1RG1) of the FREQ SELECT INPUT PORT A signal, from pins AB/3E, 3F to pins A/<P, <Q ASM 231302.
A. If the BITE test gives the maintenance message RMP1/2/3 (1RG1/2/3)/HF1 (3RE1)
Subtask 23-13-00-740-071-A - replace the XCVR-HF, 1 [3RE1] AMM 23-11-33-000-001 and AMM 23-11-33-400-001.
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring (from the HF1 transceiver (3RE1) to the RMP1 (1RG1)) of the FREQ SELECT INPUT PORT A signal (from pins AB/3E, 3F to pins A/p, q) ASM 231302.
B. Do the test given in Para. 3.C.