W DOC AIRBUS | TSM A320F

Loss of the RMP 2 Data on the Bus 1 (VHF 3 System Source)


TASK 23-13-00-810-810-A
Loss of the RMP 2 Data on the Bus 1 (VHF 3 System Source)


1. Possible Causes
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-12-00-740-001
BITE Test of the VHF System
ASM 231302
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
3. Fault Confirmation
Subtask 23-13-00-865-055-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RMP/22RG2L02
Subtask 23-13-00-860-059-A
B. Job Set-up
On the RMP 2 only, make sure that the ON/OFF switch is at ON.
Subtask 23-13-00-740-068-A
C. Test
   (1) Do the BITE test of the HF system AMM 23-12-00-740-001.
NOTE: Do this test for the VHF 3 only.
4. Fault Isolation
Subtask 23-13-00-810-059-F
A. If the test confirms the fault:
   (1) If the fault continues:
  • Do a check and repair the wiring of the COM 1 DATA OUTPUT signal (from the RMP 2 (1RG2) pins A/<P, <Q to the first terminal block) ASM 231302.
Subtask 23-13-00-740-069-A
B. Do the test given in Para. 3.C.
[Rev.8 from Aug 2018] 2026.04.04 04:25:40 UTC