W DOC AIRBUS | TSM A320F

Loss of the Tuning Data for the VHF 2 System


TASK 23-13-00-810-807-A
Loss of the Tuning Data for the VHF 2 System


1. Possible Causes
  • XCVR-VHF, 2 [1RC2]
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • wiring from VHF 2 transceiver (1RC2) to RMP 2 (1RG2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-12-00-740-001
BITE Test of the VHF System
AMM 23-12-33-000-001
Removal of the VHF Transceiver
AMM 23-12-33-400-001
Installation of the VHF Transceiver
ASM 231302
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
3. Fault Confirmation
Subtask 23-13-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RMP/22RG2L02
Subtask 23-13-00-860-056-A
B. Job Set-up
On the RMP 2 only, make sure that the ON/OFF switch is at ON.
Subtask 23-13-00-740-062-A
C. Test
   (1) Do the BITE test of the VHF system AMM 23-12-00-740-001.
NOTE: Do this test for the VHF 2 only.
4. Fault Isolation
Subtask 23-13-00-810-056-B
A. If the test confirms the fault:
   (1) If the fault continues:
   (2) If the fault continues:
  • Do a check and repair the wiring from VHF 2 transceiver (1RC2) to RMP 2 (1RG2) of the FREQ SELECT INPUT PORT A signal, from pins AB/11A, 11B to pins A/<R and <S ASM 231302.
Subtask 23-13-00-740-063-A
B. Do the test given in Para. 3.C.
[Rev.8 from Aug 2018] 2026.04.04 04:25:39 UTC