Loss of the Tuning Data for the VHF 2 System
TASK 23-13-00-810-807-A
Loss of the Tuning Data for the VHF 2 System
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-865-052-A
Subtask 23-13-00-810-056-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:39 UTC
Loss of the Tuning Data for the VHF 2 System
1. Possible Causes
- XCVR-VHF, 2 [1RC2]
- RMP-COM/NAV FREQ SEL, 2 [1RG2]
wiring from VHF 2 transceiver (1RC2) to RMP 2 (1RG2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-12-00-740-001 | BITE Test of the VHF System |
| AMM 23-12-33-000-001 | Removal of the VHF Transceiver |
| AMM 23-12-33-400-001 | Installation of the VHF Transceiver |
| ASM 231302 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
Subtask 23-13-00-865-052-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-13-00-860-056-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RMP/2 | 2RG2 | L02 |
B. Job Set-up
On the RMP 2 only, make sure that the ON/OFF switch is at ON.
Subtask 23-13-00-740-062-A On the RMP 2 only, make sure that the ON/OFF switch is at ON.
C. Test
(1) Do the BITE test of the VHF system AMM 23-12-00-740-001.
4. Fault Isolation(1) Do the BITE test of the VHF system AMM 23-12-00-740-001.
NOTE: Do this test for the VHF 2 only.
Subtask 23-13-00-810-056-B
A. If the test confirms the fault:
Subtask 23-13-00-740-063-A - Replace the XCVR-VHF, 2 [1RC2] AMM 23-12-33-000-001 and AMM 23-12-33-400-001.
- Replace the RMP-COM/NAV FREQ SEL, 2 [1RG2] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- Do a check and repair the
wiring from VHF 2 transceiver (1RC2) to RMP 2 (1RG2) of the FREQ SELECT INPUT PORT A signal, from pins AB/11A, 11B to pins A/<R and <S ASM 231302.
B. Do the test given in Para. 3.C.