W DOC AIRBUS | TSM A320F

Loss of the Data from the RMP 1 to the RMP 2


TASK 23-13-00-810-803-A
Loss of the Data from the RMP 1 to the RMP 2


1. Possible Causes
  • RMP-COM/NAV FREQ SEL, 1 [1RG1]
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • wiring from RMP 1 (1RG1) to RMP 2 (1RG2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-13-00-740-001
BITE Test of the Radio Management
ASM 231301
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
3. Fault Confirmation
Subtask 23-13-00-860-052-A
A. Job Set-up
On the RMP 1 and RMP 2 only, make sure that the ON/OFF switches are at ON.
Subtask 23-13-00-740-054-A
B. Test
Do the BITE test of the Radio Management AMM 23-13-00-740-001.
NOTE: Do this test for the RMP 2 only.
4. Fault Isolation
Subtask 23-13-00-810-052-B
A. If the test gives the maintenance message RMP1(1RG1)/RMP2(1RG2):
   (1) If the fault continues:
   (2) If the fault continues:
  • do a check and repair the wiring from RMP 1 (1RG1) to RMP 2 (1RG2) of the DIALOGUE OUTPUT signal, from pins A/BB, CC to pins A/<Z, AA ASM 231301.
Subtask 23-13-00-740-055-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:25:39 UTC