Loss of the Data from the RMP 2 to the RMP 1
TASK 23-13-00-810-801-A
Loss of the Data from the RMP 2 to the RMP 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-13-00-860-050-A
Subtask 23-13-00-810-050-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:39 UTC
Loss of the Data from the RMP 2 to the RMP 1
1. Possible Causes
- RMP-COM/NAV FREQ SEL, 2 [1RG2]
- RMP-COM/NAV FREQ SEL, 1 [1RG1]
wiring from RMP 2 (1RG2) to RMP 1 (1RG1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-13-00-740-001 | BITE Test of the Radio Management |
| ASM 231301 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
Subtask 23-13-00-860-050-A
A. Job Set-up
On the RMP 1 and RMP 2 only, make sure that the ON/OFF switches are at ON.
Subtask 23-13-00-740-050-A On the RMP 1 and RMP 2 only, make sure that the ON/OFF switches are at ON.
B. Test
Do the BITE test of the Radio Management AMM 23-13-00-740-001.
4. Fault IsolationDo the BITE test of the Radio Management AMM 23-13-00-740-001.
NOTE: Do this test for the RMP 1 only.
Subtask 23-13-00-810-050-B
A. If the test gives the maintenance message RMP2(1RG2)/RMP1(1RG1):
Subtask 23-13-00-740-051-A - replace the RMP-COM/NAV FREQ SEL, 2 [1RG2] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring from RMP 2 (1RG2) to RMP 1 (1RG1) of the DIALOGUE OUTPUT signal, from pins A/BB, CC to pins A/<X, <Y ASM 231301.
B. Do the test given in Para. 3.B.