Loss of the BUS 2 Data from the CFDIU to the VHF 2
TASK 23-12-00-810-820-A
Loss of the BUS 2 Data from the CFDIU to the VHF 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 23-12-00-865-054-A
Subtask 23-12-00-810-075-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:38 UTC
Loss of the BUS 2 Data from the CFDIU to the VHF 2
1. Possible Causes
- XCVR-VHF, 2 [1RC2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-12-00-740-001 | BITE Test of the VHF System |
| AMM 23-12-33-000-001 | Removal of the VHF Transceiver |
| AMM 23-12-33-400-001 | Installation of the VHF Transceiver |
| ASM 313203 |
Subtask 23-12-00-865-054-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-12-00-740-070-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | CFDS/CFDIU/SPLY | 2TW | J18 |
| 121VU | CFDS/CFDIU/BACK/UP | 8TW | J17 |
B. Test
Do the BITE test of the VHF system AMM 23-12-00-740-001.
4. Fault IsolationDo the BITE test of the VHF system AMM 23-12-00-740-001.
NOTE: Do this test for the VHF 2 only.
Subtask 23-12-00-810-075-B
A. If the test gives the maintenance message CFDIU (1TW)/VHF2 (1RC2):
Subtask 23-12-00-740-071-A - replace the XCVR-VHF, 2 [1RC2] AMM 23-12-33-000-001 and AMM 23-12-33-400-001.
- do a check and repair the wiring of the BUS 2 OUTPUT signal, (from VHF 2 transceiver (1RC2) pins AB/6A, 6B to the first terminal block) ASM 313203.
B. Do the test given in Para. 3.B.