W DOC AIRBUS | TSM A320F

Loss of the BUS 1 Data from the CFDIU to the VHF 1


TASK 23-12-00-810-819-A
Loss of the BUS 1 Data from the CFDIU to the VHF 1


1. Possible Causes
  • XCVR-VHF, 1 [1RC1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-12-00-740-001
BITE Test of the VHF System
AMM 23-12-33-000-001
Removal of the VHF Transceiver
AMM 23-12-33-400-001
Installation of the VHF Transceiver
ASM 313202
3. Fault Confirmation
Subtask 23-12-00-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCFDS/CFDIU/SPLY2TWJ18
121VUCFDS/CFDIU/BACK/UP8TWJ17
Subtask 23-12-00-740-068-A
B. Do the BITE test of the VHF system AMM 23-12-00-740-001.
NOTE: Do this test for the VHF 1 only.
4. Fault Isolation
Subtask 23-12-00-810-074-B
A. If the test gives the maintenance message CFDIU (1TW)/VHF1 (1RC1):
   (1) If the fault continues:
  • do a check and repair the wiring of the BUS 1 OUTPUT signal, (from VHF 1 transceiver (1RC1) pins AB/6A, 6B to the first terminal block) ASM 313202.
Subtask 23-12-00-740-069-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:25:38 UTC