W DOC AIRBUS | TSM A320F

Failure of the VHF 1 Transceiver


TASK 23-12-00-810-801-A
Failure of the VHF 1 Transceiver


1. Possible Causes
  • XCVR-VHF, 1 [1RC1]
  • wiring
  • C/B-COM/VHF/1 or C/B-COM NAV/VHF/1 [2RC1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-12-00-740-001
BITE Test of the VHF System
ASM 231201
AMM 23-12-33-000-001
Removal of the VHF Transceiver
AMM 23-12-33-400-001
Installation of the VHF Transceiver
3. Fault Confirmation
Subtask 23-12-00-740-050-A
A. Test
Do the BITE test of the VHF system AMM 23-12-00-740-001.
NOTE: Do this test for the VHF 1 only.
4. Fault Isolation
Subtask 23-12-00-865-061-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM/VHF/12RC1G09
** ON A/C NOT FOR ALL
49VUCOM NAV/VHF/12RC1G09
Subtask 23-12-00-810-050-B
B. If the test gives the maintenance message VHF1 (1RC1):
  • do a check of the circuit breaker (2RC1) status.
   (1) If the circuit breaker is closed:
  • do a check for 28DC at pin AC/2 of the VHF 1 transceiver (1RC1) ASM 231201.
     (a) If there is 28DC:
     (b) If there is no 28DC:
  • do a check for a ground signal at pin AB/3D of the VHF 1 transceiver (1RC1) ASM 231201.
       1 If there is no ground signal:
  • repair the wiring between the VHF 1 transceiver pin AB/3D and the ground terminal ASM 231201.
       2 If there is a ground signal:
  • do a check of the wiring between the VHF 1 transceiver pin AC/2 and the circuit breaker 2RC1 ASM 231201.
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
  • replace the circuit breaker 2RC1.
   (2) If the circuit breaker is open:
  • close it.
     (a) If it opens again:
       1 If the fault continues:
  • do a check for a short-to-ground at the wiring between the VHF 1 transceiver pin AC/2 and the circuit breaker 2RC1 ASM 231201.
         a If there is a short-to-ground:
  • repair the related wiring
         b If there is no short-to-ground:
  • replace the C/B-COM/VHF/1 or C/B-COM NAV/VHF/1 [2RC1] .
     (b) If the circuit breaker stays closed and the fault continues:
Subtask 23-12-00-740-051-A
C. Do the test given in Para. 3.