Loss of the BUS 1 Data from the CFDIU to the HF 1


TASK 23-11-00-810-819-A
Loss of the BUS 1 Data from the CFDIU to the HF 1


1. Possible Causes
  • XCVR-HF, 1 [3RE1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 23-11-00-740-001
BITE Test of the HF System
AMM 23-11-33-000-001
Removal of the HF Transceiver
AMM 23-11-33-400-001
Installation of the HF Transceiver
ASM 313202
3. Fault Confirmation
Subtask 23-11-00-865-053-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCFDS/CFDIU/SPLY2TWJ18
121VUCFDS/CFDIU/BACK/UP8TWJ17
Subtask 23-11-00-740-067-A
B. Test
Do the BITE test of the HF system AMM 23-11-00-740-001.
NOTE: Do this test for the HF 1 only.
4. Fault Isolation
Subtask 23-11-00-810-075-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message HF 1 NO DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring of the BUS 1 OUTPUT signal, from the HF 1 transceiver (3RE1) pins AB/4A, 4B to the first terminal block ASM 313202.
Subtask 23-11-00-810-075-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message CFDIU (1TW)/HF1 (3RE1):
   (1) If the fault continues:
  • do a check and repair the wiring of the BUS 1 OUTPUT signal (from the HF 1 transceiver (3RE1) pins AB/4A, 4B to the first terminal block) ASM 313202.
Subtask 23-11-00-740-068-A
B. Do the test given in Para. 3.B.