Display of the CAT 2 Message (INOP SYS) on the ECAM STATUS Page
TASK 22-83-00-810-903-A
Display of the CAT 2 Message (INOP SYS) on the ECAM STATUS Page
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-201-A 4. Fault Isolation
Subtask 22-83-00-810-196-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:34 UTC
Display of the CAT 2 Message (INOP SYS) on the ECAM STATUS Page
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
Subtask 22-83-00-710-201-A 4. Fault Isolation
Subtask 22-83-00-810-196-A
A. If the test gives the maintenance message TEST OK, no other maintenance action is necessary.
Subtask 22-83-00-810-197-A B. If the test is not OK:
- Do the trouble shooting procedure related to the maintenance message.