Unsatisfactory Autoland
TASK 22-83-00-810-898-A
Unsatisfactory Autoland
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-194-A
Subtask 22-83-00-810-188-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:34 UTC
Unsatisfactory Autoland
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-96-00-710-001 | Operational Test of the AFS |
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
Subtask 22-83-00-710-194-A
A. Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationSubtask 22-83-00-810-188-A
A. If there is an Unsatisfactory Autoland entry in the log-book report:
(2) If these tests are correct, find if there is:
(b) If no, no maintenance action is necessary.
(3) If there are many Unsatisfactory Autoland entries in the log-book for the same aircraft:
- Do the operational test of the AFS AMM 22-96-00-710-001 and the LAND CAT III capability test AMM 22-97-00-710-001.
(2) If these tests are correct, find if there is:
- A maintenance message related to RA and/or ILS fault(s) in the Post Flight Report, and/or
- An entry related to RA and/or ILS fault(s) in the log-book report:
(b) If no, no maintenance action is necessary.
(3) If there are many Unsatisfactory Autoland entries in the log-book for the same aircraft:
- Get the data from the DFDR or QAR and send them to AIRBUS for analysis.