CAT 2 (INOP SYS) on the SD
TASK 22-83-00-810-896-A
CAT 2 (INOP SYS) on the SD
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-190-A 4. Fault Isolation
Subtask 22-83-00-810-182-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:34 UTC
CAT 2 (INOP SYS) on the SD
1. Possible Causes
- PFD-CAPT [2WT1]
- DMC-1 [1WT1]
wiring of the PFD OWN VALID discrete from the DMC 1 (1WT1) to the first terminal block - PFD-F/O [2WT2]
- DMC-2 [1WT2]
wiring of the PFD OPP VALID discrete from the DMC 2 (1WT2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 228504 | |
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 22-83-00-710-190-A 4. Fault Isolation
Subtask 22-83-00-810-182-A
A. If the test gives the maintenance messages:
AFS: CHK DMC 1 - FMGC 1 CKT (ISSUED BY: FG1) and
AFS: CHK DMC 1 - FMGC 2 CKT (ISSUED BY: FG2)
(1) Do the test given in Para. 3 with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at CAPT/3.
(a) If the fault continues:
Subtask 22-83-00-810-183-A AFS: CHK DMC 1 - FMGC 1 CKT (ISSUED BY: FG1) and
AFS: CHK DMC 1 - FMGC 2 CKT (ISSUED BY: FG2)
(1) Do the test given in Para. 3 with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at CAPT/3.
(a) If the fault continues:
- replace the PFD-CAPT [2WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the PFD OWN VALID discrete from the DMC 1 (1WT1) to the first terminal block ASM 228504.
B. If the test gives the maintenance messages:
AFS: CHK DMC 2 - FMGC 2 CKT (ISSUED BY: FG2) and
AFS: CHK DMC 2 - FMGC 1 CKT (ISSUED BY: FG1)
(1) Do the test given in Para. 3 with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at F/O/3.
(a) If the fault continues:
Subtask 22-83-00-710-191-A AFS: CHK DMC 2 - FMGC 2 CKT (ISSUED BY: FG2) and
AFS: CHK DMC 2 - FMGC 1 CKT (ISSUED BY: FG1)
(1) Do the test given in Para. 3 with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at F/O/3.
(a) If the fault continues:
- replace the PFD-F/O [2WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring of the PFD OPP VALID discrete from the DMC 2 (1WT2) to the first terminal block ASM 228504.
C. Do the test given in Para. 3.