FM 1/FM 2 Incoherence (Independant Operation)
TASK 22-83-00-810-892-A
FM 1/FM 2 Incoherence (Independant Operation)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-184-A
Subtask 22-83-00-865-105-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:34 UTC
FM 1/FM 2 Incoherence (Independant Operation)
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| AWM 228530 | |
| AWM 228531 | |
| AWM 228536 | |
| AWM 228537 |
Subtask 22-83-00-710-184-A
A. Not applicable.
4. Fault IsolationSubtask 22-83-00-865-105-A
A. Table of the circuit breakers used in this procedure:
Subtask 22-83-00-810-175-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AUTO FLT/FMGC/1 | 10CA1 | B02 |
| 121VU | AUTO FLT/FMGC/2 | 10CA2 | M17 |
B. If the message is still present in the scratchpad:
(2) If the fault continues:
(a) Do a check of:
Subtask 22-83-00-710-185-A - perform a C/B reset (10CA1 and 10CA2) of both FMGCs.
(2) If the fault continues:
(a) Do a check of:
- the NDB cycle is the same for the two FMGCs.
- the P/N is the same for the two FMGCs.
- the wiring of the pin programming of the two FMGCs AWM 228530, AWM 228531, AWM 228536 and AWM 228537
- replace the FMGC-1 [1CA1] , AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the FMGC-2 [1CA2] , AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
C. Not applicable.