W DOC AIRBUS | TSM A320F

Failure of the FMGC2 for the Cabin Pressure Controller


TASK 22-83-00-810-877-A
Failure of the FMGC2 for the Cabin Pressure Controller


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 21-31-00-710-002
Operational Test of the Pressure Control and Monitoring
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
3. Fault Confirmation
Subtask 22-83-00-710-180-A
A. Test
   (1) Do the operational test of the pressure control and monitoring AMM 21-31-00-710-002.
4. Fault Isolation
Subtask 22-83-00-810-159-A
A. If the test gives the maintenance message FMGS2 OUT OF RANGE:
Subtask 22-83-00-710-181-A
B. Do the test given in Para. 3.