W DOC AIRBUS | TSM A320F

Access to the AFS/TEST REPORT Page Related to the FMGC 1 Not Possible


TASK 22-83-00-810-873-A
Access to the AFS/TEST REPORT Page Related to the FMGC 1 Not Possible


1. Possible Causes
  • FMGC-1 [1CA1]
  • wiring of the SIDE 1 discretes from the FMGC 1 (1CA1) to the ground points
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228401
3. Fault Confirmation
Subtask 22-83-00-710-174-A
A. Test
   (1) Not applicable, the fault is evident.
4. Fault Isolation
Subtask 22-83-00-810-155-A
A. If the AFS/TEST REPORT page related to the FMGC 1 is not shown on the MCDU:
   (1) If the fault continues:
  • do a check and repair the wiring of the SIDE 1 discretes from the FMGC 1 (1CA1) to the ground points ASM 228401.
[Rev.8 from Aug 2018] 2026.04.04 04:25:33 UTC