Access to the AFS/TEST REPORT Page Related to the FMGC 1 Not Possible
TASK 22-83-00-810-873-A
Access to the AFS/TEST REPORT Page Related to the FMGC 1 Not Possible
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-174-A
Subtask 22-83-00-810-155-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:33 UTC
Access to the AFS/TEST REPORT Page Related to the FMGC 1 Not Possible
1. Possible Causes
- FMGC-1 [1CA1]
wiring of the SIDE 1 discretes from the FMGC 1 (1CA1) to the ground points
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228401 |
Subtask 22-83-00-710-174-A
A. Test
(1) Not applicable, the fault is evident.
4. Fault Isolation(1) Not applicable, the fault is evident.
Subtask 22-83-00-810-155-A
A. If the AFS/TEST REPORT page related to the FMGC 1 is not shown on the MCDU:
- replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring of the SIDE 1 discretes from the FMGC 1 (1CA1) to the ground points ASM 228401.