Loss of the Reception of the FQI Bus by one FMGC
TASK 22-83-00-810-872-A
Loss of the Reception of the FQI Bus by one FMGC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-865-086-A
Subtask 22-83-00-810-153-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:33 UTC
Loss of the Reception of the FQI Bus by one FMGC
1. Possible Causes
- FMGC-1 [1CA1]
wiring of the FQI bus from the FMGC 1 (1CA1) to the first terminal block - FQIC [3QT]
- FMGC-2 [1CA2]
wiring of the FQI bus from the FMGC 2 (1CA2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228601 | |
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AMM 28-42-00-740-007 | Interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data |
| AMM 28-42-34-000-001 | Removal of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 28-42-34-400-001 | Installation of the Fuel Quantity-Indicating Computer (FQIC) |
Subtask 22-83-00-865-086-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-83-00-710-172-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
Subtask 22-83-00-810-153-A
A. If the test gives the maintenance message AFS : FQIC (ISSUED BY : FM1):
(1) Do the interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data AMM 28-42-00-740-007.
(a) If there is no fault codes:
1 Replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
2 If the fault continues:
1 Replace the FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
Subtask 22-83-00-810-154-A (1) Do the interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data AMM 28-42-00-740-007.
(a) If there is no fault codes:
1 Replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
2 If the fault continues:
- Do a check and repair the
wiring of the FQI bus from the FMGC 1 (1CA1) to the first terminal block ASM 228601.
1 Replace the FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
B. If the test gives the maintenance message AFS : FQIC (ISSUED BY : FM2):
(1) Do the interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data AMM 28-42-00-740-007.
(a) If there is no fault codes:
1 Replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
2 If the fault continues:
1 Replace the FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
Subtask 22-83-00-710-173-A (1) Do the interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data AMM 28-42-00-740-007.
(a) If there is no fault codes:
1 Replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
2 If the fault continues:
- Do a check and repair the
wiring of the FQI bus from the FMGC 2 (1CA2) to the first terminal block ASM 228601.
1 Replace the FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
C. Do the test given in Para. 3.