Loss of the Ground Conditions on the FMGC 2
TASK 22-83-00-810-870-A
Loss of the Ground Conditions on the FMGC 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-710-169-A 4. Fault Isolation
Subtask 22-83-00-810-151-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:33 UTC
Loss of the Ground Conditions on the FMGC 2
1. Possible Causes
- FMGC-2 [1CA2]
- LGCIU-1 [5GA1]
- LGCIU-2 [5GA2]
wiring of the NOSE GEAR OWN discrete from the FMGC 2 (1CA2) to the LGCIU 2 (5GA2) wiring of the NOSE GEAR OPP discrete from the FMGC 2 (1CA2) to the LGCIU 1 (5GA1) wiring of the ENG OWN STOP and ENG OPP STOP discretes (from the FMGC 2 (1CA2) to the diode modules (1800VD and 1801VD)) - wiring of the diode module 1800VD
- wiring of the diode module 1801VD
DIODE MODULE (1800VD) DIODE MODULE (1801VD) wiring of the FMGC OWN A discrete from the FMGC 2 (1CA2) to the FAC 1 (1CC1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 226901 | |
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228504 | |
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 22-83-00-710-169-A 4. Fault Isolation
Subtask 22-83-00-810-151-A
A. On the MCDU 2, if the LAND TEST REFUSED message comes into view:
(a) If there is no continuity:
a If there is no continuity:
Subtask 22-83-00-710-170-A - replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check of the
wiring of the NOSE GEAR OWN discrete from the FMGC 2 (1CA2) to the LGCIU 2 (5GA2) - do a check of the
wiring of the NOSE GEAR OPP discrete from the FMGC 2 (1CA2) to the LGCIU 1 (5GA1)
(a) If there is no continuity:
- repair the above wiring.
- do a check of the
wiring of the ENG OWN STOP and ENG OPP STOP discretes (from the FMGC 2 (1CA2) to the diode modules (1800VD and 1801VD)) ASM 228504.
- repair the above wiring.
- do a check of the wiring of the diode module 1800VD from pin A/8 to the first terminal block
- do a check of the wiring of the diode module 1801VD from pin A/8 to the first terminal block
a If there is no continuity:
- repair the above wiring.
- replace the
DIODE MODULE (1800VD) - replace the
DIODE MODULE (1801VD) .
- do a check and repair the
wiring of the FMGC OWN A discrete from the FMGC 2 (1CA2) to the FAC 1 (1CC1) ASM 226901.
B. Do the test given in Para. 3.