W DOC AIRBUS | TSM A320F

Loss of the Ground Conditions on the FMGC 2


TASK 22-83-00-810-870-A
Loss of the Ground Conditions on the FMGC 2


1. Possible Causes
  • FMGC-2 [1CA2]
  • LGCIU-1 [5GA1]
  • LGCIU-2 [5GA2]
  • wiring of the NOSE GEAR OWN discrete from the FMGC 2 (1CA2) to the LGCIU 2 (5GA2)
  • wiring of the NOSE GEAR OPP discrete from the FMGC 2 (1CA2) to the LGCIU 1 (5GA1)
  • wiring of the ENG OWN STOP and ENG OPP STOP discretes (from the FMGC 2 (1CA2) to the diode modules (1800VD and 1801VD))
  • wiring of the diode module 1800VD
  • wiring of the diode module 1801VD
  • DIODE MODULE (1800VD)
  • DIODE MODULE (1801VD)
  • wiring of the FMGC OWN A discrete from the FMGC 2 (1CA2) to the FAC 1 (1CC1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 226901
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228504
AMM 22-97-00-710-001
Operational Test of the LAND CAT III Capability
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
3. Fault Confirmation
Subtask 22-83-00-710-169-A
A. Test
   (1) Do the operational test of the LAND CAT III capability AMM 22-97-00-710-001.
4. Fault Isolation
Subtask 22-83-00-810-151-A
A. On the MCDU 2, if the LAND TEST REFUSED message comes into view:
   (1) If the fault continues:
   (2) If the fault continues:
   (3) If the fault continues:
  • do a check of the wiring of the NOSE GEAR OWN discrete from the FMGC 2 (1CA2) to the LGCIU 2 (5GA2)
  • do a check of the wiring of the NOSE GEAR OPP discrete from the FMGC 2 (1CA2) to the LGCIU 1 (5GA1)
ASM 228504.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check of the wiring of the ENG OWN STOP and ENG OPP STOP discretes (from the FMGC 2 (1CA2) to the diode modules (1800VD and 1801VD)) ASM 228504.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
  • do a check of the wiring of the diode module 1800VD from pin A/8 to the first terminal block
  • do a check of the wiring of the diode module 1801VD from pin A/8 to the first terminal block
ASM 228504
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
  • replace the DIODE MODULE (1800VD)
  • replace the DIODE MODULE (1801VD).
   (4) If the fault continues:
  • do a check and repair the wiring of the FMGC OWN A discrete from the FMGC 2 (1CA2) to the FAC 1 (1CC1) ASM 226901.
Subtask 22-83-00-710-170-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:33 UTC