Loss of the FWC Functions


TASK 22-83-00-810-866-A
Loss of the FWC Functions


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-97-00-710-001
Operational Test of the LAND CAT III Capability
3. Fault Confirmation
Subtask 22-83-00-710-164-A
A. Test
   (1) Do the operational test of the LAND CAT III capability AMM 22-97-00-710-001.
4. Fault Isolation
Subtask 22-83-00-865-094-A
A. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUFWS/FWC1/SPLY3WWF01
121VUEIS/FWC2/SPLY2WWQ07
Subtask 22-83-00-810-147-A
B. If the test gives the maintenance message AFS : CHK FWC 1/2 (INST SYS):
  • open the circuit breakers 2WW and 3WW
  • after 15 s, close these circuit breakers
  • do the test given in Para. 3.