W DOC AIRBUS | TSM A320F

Loss of the Reception of the DMC 1 VALID Discrete by the FMGC 2


TASK 22-83-00-810-856-A
Loss of the Reception of the DMC 1 VALID Discrete by the FMGC 2


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the PFD OPP VALID discrete (from the FMGC 2 (1CA2) to the first terminal block)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228504
AMM 22-91-00-710-001
Ground Scanning of the AFS
3. Fault Confirmation
Subtask 22-83-00-865-083-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUEIS/DMC1/SPLY10WT1E11
49VUEIS/DMC1/SWTG21WT1E09
Subtask 22-83-00-710-144-A
B. Test
   (1) Do the Ground Scanning of the AFS AMM 22-91-00-710-001.
4. Fault Isolation
Subtask 22-83-00-810-137-A
A. If the test gives the maintenance message AFS: CHK DMC1-FMGC2 CKT:
   (1) If the fault continues:
  • do a check and repair the wiring of the PFD OPP VALID discrete (from the FMGC 2 (1CA2) to the first terminal block) ASM 228504.
Subtask 22-83-00-710-145-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:25:32 UTC