Loss of the Reception of the FWC VALID Discretes by one FMGC
TASK 22-83-00-810-847-A
Loss of the Reception of the FWC VALID Discretes by one FMGC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-83-00-865-074-A
Subtask 22-83-00-810-122-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:32 UTC
Loss of the Reception of the FWC VALID Discretes by one FMGC
1. Possible Causes
- FMGC-1 [1CA1]
wiring of the FWC OWN VALID and FWC OPP VALID discretes (from the FMGC 1 (1CA1) to the first terminal block) - FMGC-2 [1CA2]
wiring of the FWC OWN VALID and FWC OPP VALID discretes (from the FMGC 2 (1CA2) to the first terminal block) - FWC-1 [1WW1]
- FWC-2 [1WW2]
wiring of the FWC VALID discrete from the FWC 1 (1WW1) to the first terminal block wiring of the FWC VALID discrete (from the FWC 2 (1WW2) to the first terminal block)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228504 | |
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
Subtask 22-83-00-865-074-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 22-83-00-710-126-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FWS/FWC1/SPLY | 3WW | F01 |
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
Subtask 22-83-00-810-122-A
A. If the test gives only the maintenance message AFS: FWC1 AND FWC 2 (ISSUED BY: FG1):
Subtask 22-83-00-810-123-A - replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring of the FWC OWN VALID and FWC OPP VALID discretes (from the FMGC 1 (1CA1) to the first terminal block) ASM 228504.
B. If the test gives only the maintenance message AFS: FWC1 AND FWC2 (ISSUED BY: FG2):
Subtask 22-83-00-810-124-A - replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring of the FWC OWN VALID and FWC OPP VALID discretes (from the FMGC 2 (1CA2) to the first terminal block) ASM 228504.
C. If the test gives the maintenance messages:
AFS: FWC1 AND FWC2 (ISSUED BY: FG1) and
AFS: FWC1 AND FWC2 (ISSUED BY: FG2):
Subtask 22-83-00-710-127-A AFS: FWC1 AND FWC2 (ISSUED BY: FG1) and
AFS: FWC1 AND FWC2 (ISSUED BY: FG2):
- replace the FWC-1 [1WW1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- replace the FWC-2 [1WW2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check of the
wiring of the FWC VALID discrete from the FWC 1 (1WW1) to the first terminal block ASM 228504.
- repair the above wiring.
- do a check and repair the
wiring of the FWC VALID discrete (from the FWC 2 (1WW2) to the first terminal block) ASM 228504.
D. Do the test given in Para. 3.